Testing/Operating: After installation, test the system to verify each signal operates and
establish a program for periodic testing of the device. Provide copy of these instructions to all
operating personnel.
Ordering Replacement Parts and Accessories: If your unit requires a part
not listed below, it must be replaced or repaired.
Description
LED Lamp
Corner Mount Bracket Assembly
Wall Mount Bracket Assembly
Replacing the LED Lamp:
1. SHOCK HAZARD! – Disconnect power. Allow the lamp to cool.
2. Remove the set screw located at the bottom of the dome.
3. Grasp the top of the dome and push it down while turning dome counterclockwise.
4. Remove dome and ensure the gasket between the dome and base is secured.
5. Grasp lamp near the base and gently push toward socket while turning counterclockwise.
6. Insert the new lamp while gently pushing it toward the socket and turning clockwise.
7. Before replacing dome, ensure the gasket is properly seated on the housing base.
8. Place dome over base and aligning recesses inside dome lip with four pins on the base.
Push down on the dome and turn clockwise until it locks in place (approximately ¾").
9. Replace set screw on the bottom of the dome.
10. Test the light for proper operation.
Technical Assistance:
signalsupport@fedsig.com.
A return authorization is required. Contact your Authorized Distributor or
Repair Service:
Federal Signal Customer Support at +1-708-534-4756 or iordersup@fedsig.com. Defective
products under warranty will be repaired or replaced at Federal Signal's discretion. Lamp
failures excluded.
Product Returns: A return authorization is required from Federal Signal prior to returning the
product. Contact your Authorized Distributor for more information or to request a product return.
2645 Federal Signal Drive
University Park, Illinois 60484
Additional translations available at www.fedsig.com
Traducciones adicionales disponibles en www.fedsig.com
Customer Support 1-800-344-4634
+1-708-534-4756, iordersup@fedsig.com
Technical Support 1-800-755-7621
+1-708-587-3587, signalsupport@fedsig.com
Part Number
K14702196A
LCMB2
LWMB2
Contact our technical support team at +1-708-587-3587 or
LCMB2
25500629A Rev. A0 0320
LWMB2