GAS SUPPLY TRANSFORMATION

The appliance is marketed with indications of the gas mains used by the manufacturer
for inspections.
If the gas mains do not correspond to the one used for inspection, before connecting
the gas mains, the installation technician must "transform" the appliance and indicate
the type of gas in use on the plate.
Important
After "transforming" the appliance to the gas mains in use, make sure there are no
gas leaks or operating defects, test the appliance and indicate the type of gas in use
on the identification plate.
To "transform" and adapt the appliance to the gas mains in use, close the gas supply
faucet and perform the listed operations.
– Burner nozzle replacement.
– primary burner air adjustment.
– Heat power adjustment to minimum
– pilot flame nozzle replacement
Burner nozzle replacement
1 - Remove the cook grills , the
lava stone support grills , the
grill supports and the drain con-
duit.
2 - Remove the burners.
3 - Unscrew the nozzle (A) and re-
place it with the one suited for
the gas used.
A
- 15 -
LAVA STONE GRILLS
IDM-34601900300.tif