Description/Intended Use:
• The Stryker Hip Arthroscopy Instruments (hereafter hip instruments) are intended
to be used in operative arthroscopic procedures in the hip joint.
• The hip instruments consist of reusable instruments and non-sterile, single-use
blades:
Catalog number
Reusable Instruments:
0242-200-001
0242-200-002
0242-200-003
0242-200-004
0242-200-005
0242-200-006
0242-200-007
0242-200-008
0242-200-009
0242-200-010
0242-200-011
0242-200-012
0242-200-013
0242-200-014
0242-200-015
0242-200-016
0242-200-017
0242-200-018
0242-200-019
0242-200-020
0242-200-021
0242-200-022
0242-200-023
0242-200-027
Non-Sterile, Single-Use Blades:
0242-200-024
0242-200-025
0242-200-026
Contraindications:
The hip instruments are NOT intended for use where one or more of the following
conditions exist:
• Pathological conditions of the tissue to be treated
• Physical conditions that would retard healing, such as blood supply limitation and
infection
• Conditions which tend to limit the patient's ability or willingness to follow
instructions during the healing period.
Warnings:
• These instructions are not meant to replace proper training in surgical technique
or hip arthroscopy. It is imperative that the surgeon and operating theater staff
are fully conversant with operative arthroscopic procedures in the hip joint prior to
using the hip instruments.
• Inspect the instruments prior to each use and after each cleaning/sterilization
cycle to ensure proper safety and functionality. Do not use damaged, worn, or
bent instruments, as these may not function properly and may harm the patient
or user.
• Do not attempt to bend, straighten, or repair the hip instruments, as this will
compromise instrument integrity and potentially harm the patient or user. For
replacement or repair, contact your Stryker representative.
• Handle hip instruments with care. Some hip instruments have sharp edges that
can puncture skin.
• The hip instruments are provided NON-STERILE and must be cleaned, disinfected,
and sterilized prior to the first and every subsequent use. For proper cleaning,
disinfection, and sterilization, follow the reprocessing instructions provided in
this guide.
Description
5.5mm Slotted Cannula
6.5mm Slotted Cannula
4.0mm Cannulated Switching Stick
5.5mm Cannulated Switching Stick
6.5mm Cannulated Switching Stick
Hip Biter, Straight
Hip Biter, 15° Up
Hip Grasper, Right
Hip Grasper, Left
Hip Grasper, Straight
Hip Suture Passer, Left
Hip Suture Passer, Right
Hip Suture Passer, Straight
Hip Suture Passer, 35° Up
Hip Suture Grasper
Suture Cutter
Hip Knot Pusher
Hip Curette, 20°
Hip Rasp, 30° Up
Hip Tissue Liberator, 20°
Hip Probe, 90°
Curved Hip Probe
Microfracture Pick, Straight
Switching Stick Handle
Curved Hip Blade, Sharp Tip
Straight Hip Blade, Blunt Tip
Straight Hip Blade, Sharp Tip
4