Escutcheon Installation
Secure backplate (3) to rough-in body (4) using
4 screws (5) provided. Note: Be sure backplate
is oriented front side forward and markings
are visible. If mounting to an uneven surface,
apply appropriate sealant around the backplate to
supplement rubber seal. Align holes in escutcheon
(6) with cartridges and slide escutcheon (6) onto
backplate. Slide sleeve (7) onto escutcheon (6)
and secure by threading trim nut (8) onto diverter
sleeve. Do not overtighten. Slide diverter base
(9) over trim nut (8). For thick wall installation,
an optional extension kit is available to
accommodate up to 1" of additional wall
thickness. Order RP100669.
Installation and Adjustment of the Temperature Handle. Failure to do so
may cause injury. Please complete the following steps carefully.
D.
7
1
5
6
Adjust temperature limit stop
Turn on water supplies; LET WATER RUN AT
FULL HOT TO ENSURE WATER IS AS HOT
AS POSSIBLE. Place a thermometer in a plastic
tumbler and hold tumbler in water stream.
Aligning the splines, place temperature handle
(1) onto end of cartridge stem (2). Rotate handle
until desired maximum temperature is achieved
(not more than 120° or lower, as mandated by
local plumbing code).
4
5
3
2
8
C.
10
Volume Handle Installation
Slide volume control handle (10) over cartridge,
aligning flat surfaces inside handle with flat
surfaces on sides of cartridge. Handle lever
should point downward (6 o'clock) in the off
position. Secure handle with set screw (11).
Note: Set screw should be started in handle
before installing onto cartridge. Then tighten
set screw by placing Allen wrench through
access hole in trim sleeve.
Remove temperature handle (1). Replace handle
onto cartridge stem with handle limit stop (4)
against volume handle limit stop (3), as shown.
Secure temperature handle (1) onto valve stem
with screw (5). Ensure O-ring (6) is assembled
on handle cap (7). Install handle cap by pressing
it into place on top of the temperature handle
(1). Secure cap by tightening screw (8) from the
underside of the handle.
5
11
3
4
106513 Rev. A