8 - Warnings for system r econfiguration
operations
After installing, programming and powering up the prod-
uct, if any addresses, connected motors or connected
control units are changed or if configurators are modi-
fied, the interface must be switched off and then on
again to enable acquisition of the modified parameters.
Maintenance and disposal
INB does not require any maintenance. The product is
made up of different types of material; some may be re-
cycled, such as plastic or electric cables, while others
must be disposed of: e.g. electronic boards.
Table C
SCS LEDS
Start-up
Normal operation
Reception of SCS command
NICE LEDS
Start-up
Initialisation
Normal operation
Command reception
Communication error with SCS in
initialisation phase
Some electronic components may contain pollutant
substances; therefore never dispose of into the environ-
ment and seek information on suitable recycling or dis-
posal systems, taking care to observe current local
standards.
To disassemble and dispose of the product, proceed as
follows:
1. Disconnect all devices from the electrical mains.
2. Remove all electrical connections.
3. Separate where possible all parts which may or must
be recycled or disposed of differently, for example
metal parts from plastic parts, electronic boards etc.
4. Sort and assign the separated materials to specialist
waster recovery and disposal centres in your local area.
Green led L1
Lit for 1s; then 5 quick flashes, then lit
for 2s
Flashes at intervals of 1s in synchro-
nous and asynchronous mode with re-
spect to L2
Changes synchronism with L2
Green led L3
Lit for 6s
Off
Off
Quick flashes
Always lit
Red led L2
Lit for 1s; then 5 quick flashes, then lit
for 2s
Flashes at intervals of 1s in synchro-
nous and asynchronous mode with re-
spect to L1
Changes synchronism with L1
Red led L4
Lit for 6s
Indicates motors connected to bus:
turns off for 0.5 s for the same num-
ber of times as the series of the motor;
pause of 2 s for each motor detected
Flashes at intervals of 1s
As per Normal Operation
Always lit
Technical specifications
Notes • For purposes of product improvements, Nice
S.p.a.reserves the right to apply modifications to the
product at any time when deemed necessary, maintain-
ing the same intended use and functionality. • All tech-
nical specifications refer to an ambient temperature of
20°C (± 5°C).
• Type: Interface (gateway) between bus "SCS" of
BTicino and Nice
• Compatibility: with bus "SCS" of BTicino; bus
"TTBus" and "BusT4" of Nice
• Max. no. devices: 4, with "series" from 1 to 8
• Power supply: 20 ÷ 35 Vdc 18mA; 22 ÷ 35 Vac
18mA
• Dimensions / weight: 41 x 52 x 18 mm / 30 g
• Operating temperature: -20° ÷ +50° C
• Housing protection rating: IP 20
English – 4