Spare parts (see page 14 + 15)
1
thermoelement
2
shut off unit
3
knob for thermoelement
4
knob for shut off unit
5
non return valve DW 16
6
ball s-unions
7
safety set for temperature control 95041000
8
safety set for flow control
9
escutcheon
10 filter packing
11 knob for shut off unit
12 non return valve DW15
13 hose connection
14 o-ring 20x1
15 allen key screw M5x25
16 hose connection
Fault
Insufficient water
Crossflow, hot water being
forced into cold water pipe, or
vice versa, when mixer is closed
Spout temperature does not cor-
respond with temperature set
Temperature regulation not pos-
sible
Shower or spout dripping
Instantaneous heater didn't work
with thermostat
English
17 knob for thermoelement
94282000
18 wall support + cover
94149000
19 cover
96606000
20 support
96607000
21 tile-matching-disk
95033000
22 mounting set
94140000
23 clips for Cassetta'C, Ø 22 mm
24 shelf Cassetta'C chrome plated
95042000
25 hand shower Verso Multi
96467000
26 hand shower Verso Vario
96922000
27 filter packing
98923000
28 flow-restrictor-set
96737000
29 shower holder
98556000
30 hose 1,75 m
98140000
31 hose 1,50 m
97664000
98556000
Cause
- Supply pressure inadequate
- Filters are dirty
- Shower filter seal dirty
- Non return valve hasn't moved
back
- Backflow preventers dirty or
leaking
- Thermostat has not been ad-
justed
Hot water temperature too low
- MTC-thermo cartridge calcified
- Dirt or sedimentation on valve
seat, shut-off unit damaged
- Flow limiter in handshower isn't
removed
- Filters are dirty
- Non return valve hasn't moved
back
- Ecostop ring isn't removed
Remedy
- Check water pressure
- Cleaning the filter in the water
connection and at the thermostat
cartridge
- Clean filter seal between show-
er and hose
- Exchange non return valves
- Clean backflow preventers, ex-
change if necessary
- Adjust thermostat
Increase hot water temperature
to 42 °C to 65 °C
- Exchange MTC-thermo cartridge
- Clean or exchange shut-off unit
- Remove flow limiter
- Clean the filter / exchange filter
- Exchange non return valves
- Remove ecostop ring (A)
98505000
97983000
97984000
97985000
97986000
96179000
96189000
28642000
28778000
28779000
94246000
96708000
98522000