Safety Notes; Technical Data - Hansgrohe Talis Classic 14145 Serie Manual Del Usuario

Ocultar thumbs Ver también para Talis Classic 14145 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
Install the iBox always above the bath-tup. If parts of the
iBox will broken, the water can flow in there!
The hot and cold supplies must be of equal pressures.
Assembly (see page 33)
Important! The fitting must be installed, flushed and
tested after the valid norms.
Important! Do not use silicone containing acetic acid!
Operation
The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
The flow is changed from bath to shower function by
pulling the knob at the upper side of the spout. After
shutting off the water flow, the mixer returns automatically
to the bath function.
Fault
Mixer stiff
Mixer dripping
Diverter not operating
Hot water temperature too low, no
cold water.
Instantaneous water heater starts up
when cold water is selected.

English

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0,3 MPa:
Tub outlet
Shower outlet
anti-pollution function
Hansgrohe single lever mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
To adjust the hot water limiter on single lever mixers, please
see page 35.
No adjustment is necessary when using a continuous flow
water heater.
Maintenance
The safety device must be checked regularly according
to DIN EN 1717 in accordance with national or regional
regulations (at least once a year).
Spare parts (see page 3)
Cause
- Cartridge defective, calcified
- Cartridge defective, sedimentation
- Residue
- Water pressure to low
- Diverter defective
- Hot water limiter incorrectly set
- Crossflow
max. 1 MPa
0,1 – 0,5 MPa
max. 80°C
approx. 27 l/min
approx. 23 l/min
Remedy
- Exchange cartridge
- Exchange cartridge
- Clean converter / grease O-
rings
- Increase water pressure
- Exchange diverter
- Set hot water limiter
- Exchange cartridge
1,6 MPa
65°C

Publicidad

Tabla de contenido
loading

Tabla de contenido