Dip1 Function; Dip2 Function; Dip3 Function; Dip4 Function - Key Automation CT1RS Instrucciones Y Advertencias Para Su Instalación Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
EN

6.4 - DIP1 function

AUTOMATIC CLOSURE
If enabled after complete opening, it remains open for a time set with TR1 from 1 Sec
to 120 Sec.

6.5 - DIP2 function

STEP-BY-STEP The SBS function is subordinate to the setting of the DIP3.
The SEQ function is the equivalent of the SBS function. If DIP 2=OFF then the SBS
command executes: open-stop-close-stop-open. If DIP2=ON then the PP command
executes: open-close-open.

6.6 - DIP3 function

CONDOMINIUM FUNCTION
An SBS opening command brings the gate to full opening, no other command is
considered (except for the STOP command that blocks the automation). A closing SBS
command behaves normally: if DIP2 is set to OFF it executes the STOP - OPEN ALL
command, if DIP2 is set to ON it executes the OPEN ALL command.

6.7 - DIP4 function

OUTPUT P.OUT 24Vdc
IF SET TO OFF, A 24V LIGHT IS CONNECTED:
- It flashes slowly if the motor is in the opening movement.
- It flashes quickly if the motor is in the closing movement.
- Steady light on if the motor is stopped and not in closing.
IF SET ON ON:
Perform the photocell test

6.8 - DIP5 function

INPUT STOP
If set on OFF ► STOP input (NC)
IF set on ON ► 8K2 edge safety input

6.9 - DIP6 function

OUTPUT FLASH
If set to OFF it flashes during movement.
If set to ON, it remains on during movement and for the next 10s.

6.10 - DIP7 function

SLOWING SPEED
Determines the slowing speed.
24
OFF
NOT ENABLED
ENABLED
OFF
STEP-BY-STEP
OPEN-CLOSE
OFF
DO NOT
ENABLED
ENABLED
OFF
GATE OPEN LIGHT
PHOTO TEST
OFF
STOP
SAFETY
(NC)
OFF
COURTESY
FLASHING LIGHT
OFF
LOW
ON
ON
ON
ON
ON
(8K2)
ON
LIGHT
ON
HIGH

Publicidad