5 - TESTING AND COMMISSIONING THE AUTOMATION SYSTEM
The system must be tested by a qualified technician, who must
perform the tests required by the relevant standards in relation
to the risks present, to check that the installation complies with

5.1 Testing

All system components must be tested following the procedures
described in their respective operator's manuals;
ensure that the recommendations in Chapter 1 - Safety Warnings
- have been complied with;
check that the gate or door is able to move freely once the
automation system has been released and is well balanced,
meaning that it will remain stationery when released in any position;
check that all connected devices (photocells, sensitive edges,

5.2 Commissioning

Once all (and not just some) of the system devices have passed
the testing procedure, the system can be commissioned;
the system's technical dossier must be produced and kept for
10 years. It must contain the electrical wiring diagram, a drawing
or photograph of the system, the analysis of the risks and the
solutions adopted to deal with them, the manufacturer's declaration
of conformity for all connected devices, the operator's manual for
every device and the system maintenance plan;
fix a dataplate with the details of the automation, the name of
the person who commissioned it, the serial number and year of
construction and the CE marking on the gate or door;
also fit a sign specifying the procedure for releasing the system
by hand;
6 - FURTHER DETAILS - ADVANCED MENU
The Advanced menu allows the system to be further customised
by modifying parameters not accessible from the basic menu.
To access the ADVANCED menu, press the MENU button and
hold it down for 5 seconds.
PARAMETERS
SP.h.
1
Ph.2.
2
tP.h.
3
Ed.m.
4
iE.D.
5
30
DESCRIPTION
Use of PHOTO1 when starting from closed
0 = PHOTO1 is checked
1 = The gate starts even with PHOTO1 excited
Use of PHOTO2
0 = Enabled during both opening and closing AP/CH
1 =Only enabled during opening AP
Photo-device test
0 = off
1 = PHOTO1 on
2 = PHOTO2 on
3 = PHOTO1 and PHOTO2 on
STOP/EDGE input selection
0 = STOP contact (NC)
1 = Resistive safety edge (8k2)
2 = Contact safety edge (NC)
Sensitive edge tripping mode
0= only tripped during closure with direction reversal
1 = stops the automation (during both opening and
closure) and retreats from the obstacle
the relevant regulatory requirements, especially the EN12445
standard which specifies the test methods for gate and door
automation systems.
emergency buttons, etc.) are operating correctly by performing
gate or door opening, closing and stop tests using the connected
control devices (transmitters, buttons or switches);
perform the impact measurements as required by the EN12445
standard, adjusting the control unit's speed, motor force and
deceleration functions if the measurements do not give the
required results, until the correct setting is obtained.
draw up the declaration of conformity, the instructions and
precautions for use for the end user and the system maintenance
plan and consign them to the end user;
ensure that the user has fully understood how to operate the
system in automatic, manual and emergency modes;
the end user must also be informed in writing about any risks and
hazards still present;
warning - after detecting an obstacle, the gate or door stops
during its opening travel and automatic closure is disabled; to
restart operation, the user must press the control button or use
the transmitter.
To modify ADVANCED MENU parameters, proceed as described
for the BASIC MENU.
N.B. Some default functions/display items may vary with respect to
the type of motor selected.
DEFAULT
1
0
0
0
0
MIN
MAX
UNIT
0
1
0
1
0
3
0
2
0
1