INSTALLATION

5.1 GENERAL CONSIDERATIONS

In the following paragraphs there are some
guidelines to follow in order to obtain the maximum
performance of the product purchased.
The following instructions are nevertheless subject
to compliance with any laws and national, regional
and municipal regulations in force in the country
where the product is installed.
Installation must be performed by qualified
personnel in compliance with the UNI 10683
standard.

5.2 SAFETY PRECAUTIONS

The responsibility of the works carried out in the
area where the stove will be installed falls, and
remains, on the user; the latter is also entrusted
with the execution of the inspections related to the
installation solutions proposed.
The user must comply with all local, national and
European safety regulations.
The appliance must be installed on floors with
adequate load bearing capacity.
The stove removal and installation instructions
must only be performed by specialist technicians.
It is always recommended that users contact our
after-sale service to request qualified technicians.
In the case other technicians are involved, it is
recommended to verify their actual abilities. The
person in charge of the installation, before starting
assembly or disassembly of the stove, must comply
with the safety precautions required by law and in
particular with:
A) do not operate in adverse conditions;
B) must operate in perfect psychophysical
conditions and must check that the personal
protective equipment, are intact and functioning
perfectly;
C) must wear safety gloves;
D) must wear safety shoes;
E) must use electrical insulated tools;
F) must ensure that the area affected by the
phases of assembly and disassembly is free
from obstacles.
10

5.3 PLACE OF INSTALLATION OF STOVE

On page 36 of this manual, the minimum clearances
are shown, expressed in cm, which must be
respected when positioning the stove with respect
to combustible materials and objects.
Protect all structures which could ignite if exposed
to excessive heat.
Floors consisting of flammable material such as
for example: wood, parquet, linoleum, laminate or
covered with carpets, must be protected by a flame
retardant base under the stove, of a sufficient size.
This base can be, for example, in steel, pressed
slate, glass or stone and must cover the floor in the
area below the stove and the flue connecting pipe
and must protrude at least 50 cm in front.
The manufacturer declines all responsibility for
any variations in the characteristics of the material
constituting the floor under the protection.
Any wooden elements (e.g. beams) or combustible
materials located near the stove must be protected
with fireproof material.
Flammable walls or elements must be kept at a
distance of at least 150 cm from the stove.
Provide a technical space accessible for possible
maintenance.
Remember to respect the minimum clearance from
flammable materials (x) shown on the ID plate of
the pipes used for the chimney (fig. 5.2).
Pi = Flammable wall
Pp = Floor protection
It is prohibited to install the stove in bedrooms,
small rooms and environments having potentially
explosive dusts in the atmosphere.
Pi
80 cm
07/2021 - EN
Pi
Pp
Product images are purely indicative
Fig. 5.2