8.4 MAIN MENU
8.5
SETTING THE TEMPERATURE
The desired room temperature is set using the
Temp+ and Temp- keys on the panel. The settable
values are from 15 to 30°C. If in IDRO PLUS mode,
the maximum settable value is defined in par. 68
8.6 Setting the Operating Program
The operating program represents the stove
heating power. The program can be set using the
PROG+ and PROG- keys and it ranges from 1,
minimum power, to 5, maximum power.
8.7 Turning on the stove
To turn on the stove, it is necessary to press the
ON/OFF button for a few seconds. The stove will
automatically proceed with the ignition and heating
phase. If it is the first ignition, and therefore the
first load of pellets, it will be necessary to perform
several ignition cycles so that the pellets enter the
supply circuit. Even in the case of re-ignition, after
an automatic switch-off due to the lack of pallets
(Error Code 5), there may be an ignition error due
to the fact that the pellet supply circuit is empty.
If the stove has not performed a correct ignition,
the next ignition will be with a reduced amount of
pellets based on the auger power setting during
ignition, settable from 1 to 5 (parameter code 25).
If the stove is started while it is still in the cooling
phase, the stove will switch to waiting mode until
the fume temperature has dropped below the
stove off temperature (parameter code 36).
8.8 Turing off the stove
To turn off the stove, simply press the ON/OFF
button, with the LCD display lit up. By means of
controlled cooling, the system will bring the stove
to the off status.
8.9 Resetting System Errors
The stove reports any detected fault by means of
an error code and a comment. Before turning the
stove on again, it is necessary to reset all errors by
pressing the STOP key for about 3 seconds and
in any case until the error message on the LCD
display disappears. The last 10 errors are saved
in a non-volatile memory and can be viewed by
entering the ERROR LOG menu.
8.10 Heating Mode
The heating mode can be changed at any time
by checking both the programme and the set
temperature using the keys present and following
the instructions on the display and panel itself.
The stove will automatically adjust the power
delivered according to the program and the room
temperature measured by the special probe.
18
8.11 Pellet Saving Mode
If, during the heating phase, the room temperature
exceeds the delta T value set in system parameter
64, the stove will enter pellet saving mode and
start cooling. The stove will restart automatically
if the room temperature drops below the set
temperature for at least 1 minute. By default, if
parameter 100 is set to 0 the function is disabled.
The settable temperature value ranges from 1 to
15°C.
8.12 Automatic or Manual Mode
The stove can be operated manually, being
switched on and off by the operator, or automatically
by means of the built-in weekly programmer or
time which turn the stove on and off automatically
at set times as required. To change the mode,
press the SET key on the panel. The selected
mode will always be indicated on the display.
8.13 Manual
The stove is controlled manually only and therefore
it must be turned on and off by using the ON/OFF
button.
8.14 Auto
In addition to being manually turned on and off,
the stove also controls the settings in the timer
and the weekly programmer, by turning on an off
at the set times and days.