5/ Fit the device in an accessible place. If using PER pipes, we strongly recommend that a
thermostatic regulator be fitted to the water heater outlet. It will be set according to the
performances of the equipment used.
6/ Refer to installation figures fig.2.
7/ This device is intended for use at a maximum altitude of 3000 m.
8/ Vertical wall fixing of the water heater: to allow the potential exchange of the heating element,
let a free space above the water heater.
9/ Before removing the cover, ensure that power is disconnected to avoid any risk of injury or
electrocution.
10/ The electrical installation must include upstream of the device a pole cut out (circuit breaker
or fuse) in accordance with local installation rules.
11/ If the supply cord is damaged, it must be replaced by a special cord or assembly available
from the manufacturer or its service agent.
12/ Always connect the earth conductor of the cable to the earth ground wire or connect the earth
conductor to the appropriate terminal identified by the symbol
13/ Mandatory to install a safety device in a frost safety area (or other new pressure relief device)
on the input of the water heater, which will meet the local standards.
14/ The drain of the pressure relief device must be operated periodically to remove scale deposits
and verify that it isn't blocked.
15/ No hydraulic accessory shall be located between the safety device and the cold water inlet. A
pressure reducer (not included) is necessary on the main supply when the pressure is greater
than 0.5 MPa (5 bars).