General Characteristics - Cembre B1300PL Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1. GENERAL CHARACTERISTICS

Rated operating pressure
Oil reservoir capacity
Dimensions (Fig. 5 page 30)
Weight with battery
Motor
Operating temperature
Recommended oil
Operating speed
Safety
Rechargeable battery
Weight
(1)
Acoustic noise
(2)
Vibrations
(1)
Directive 2006/42/EC, annexe 1, point 1.7.4.2 letter u
L
= weighted continuous acoustic pressure level equivalent.
pA
L
= maximum value of the weighted acoustic displacement pressure at the work place.
pCPeak
L
= acoustic power level emitted by the machine.
WA
(2)
Directive 2006/42/EC, annexe 1, point 2.2.1.1
Weighted root mean square in frequency of the acceleration the upper limbs are exposed to for each biodynamic
reference axis. Tests carried out in compliance with the indications contained in EN ISO 5349-1/2 Standard, and under
operating conditions much more severe than those normally found.
Battery charger ASC30-36
Input
5
bar (psi)
3
cm
(cu. in.)
mm (inches)
kg (lbs)
V DC
°C (°F)
type
V / Ah (Wh)
kg (lbs)
dB
2
m/s
B1300PL
EU
type
27044000
V / Hz (W)
700 (10,000)
290 (17.7)
354 x 239 x 102.5 (13.9 x 9.4 x 4)
4 (8.8)
18
-15 to +50 (+5 to +122)
ENI ARNICA ISO 32
or equivalents
twin speed operation and automatic switching
from a rapid advancing speed to a slower, more
powerful working speed
maximum pressure valve
CB1840L Li-Ion
18 / 4.0 (72)
0,66 (1.45)
L
66,9 (A)
L
86,9 (C)
pA
pCPeak
0,398
B1300PLE
B1300PLT
UK
AUS/NZ
27045000
27047000
220 - 240 / 50 - 60 (85)
L
74,9 (A)
WA
B1300PLA
USA/CAN
27046000
115 / 60 (85)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

B1300plaB1300pleB1300plt

Tabla de contenido