ATTENTION: it is necessary to turn off the
control unit power before doing the operations
mentioned here below. Please pay attention to the
way you connect the removable modules.
PLUGGING THE RECEIVER MODULE IN
WARNING: we suggest to use the external aerial
(model: ANS433) in order to guarantee the maximal
range.
WARNING LIGHT DESCRIPTION
The warning light shows in real time the state of the
gate:
STOP
light off
IN PAUSE
light always on
DURING OPENING the light flashes slowly (2 Hz)
DURING CLOSING the light flashes rapidly (4 Hz)
TERMINAL CONNECTION
1.
Antenna
2.
Antenna shield.
3.
Opening control for the connection
of: control devices with normally
open contact, TTNC, VRD
4.
Opening controls for pedestrian
access for the connection of:
control devices with normally open
contact, TTNC, VRD
5.
Stop command
Contact normally closed
6.
Common (-)
7.
Photoelectric cell 1
Contact normally closed
8.
Photoelectric cell 2
Contact normally closed
9.
Common (-)
10.–11.
Power output 24 VAC for
photocells and other accessories
11.–12.
Photocell TX power supply for
functional tests
13.–14.
Electric lock or bolt 12 VAC
14.–15.
Warning light 24 VAC 3W
16.–17.
Contact for area lighting
230 VAC 10 A
18.–19.
Flashing light 230 VAC 40 W
20.
Power output 230 VAC for motor
2 in opening phase
21.
Common motor 2
22.
Power output 230V for motor 2 in
closing phase
23.
Power output 230 VAC for motor 1
in opening phase
24.
Common motor 1
25.
Power output 230 VAC for motor 1
in closing phase
26.
Neutral 230 VAC
27.
Power phase 230 VAC
TECHNICAL SPECIFICATIONS
Power supply
Max motors load
Max accessories load powered 24V
Working temperature
Protection fuse
Dimensions
Weight
IP protection
17
230 VAC 50 / 60 Hz
700 W
10 W
-20°C ÷ +60°C
F1 = 5 A for line 230 VAC
295 x 230 x 100 mm
1600 g
55