FAST CLOSING TIME AFTER SLOWING DOWN DURING CLOSING
When a slowing down time different from 0 s is set, it is possible
that the gate speed is not sufficient to trigger the lock during
closing. For this reason, after the end of the slowing down phase,
it is possible to close the gate at a normal speed (without slowing
down) for a time to be set between 0 and 120 s (± 0,5).

MOTOR POWER

This menu permits to adjust the motor power from 30 to 100%
with a scanning of ±0,5.

START OFF

When the gate is at a standstill and is going to move, it is
contrasted by the starting inertia. As a consequence of this, if the
gate is very heavy the gates might not move. By activating the
start off function, it is possible to win the initial inertia thanks to
the motor start to the maximum of the power for 2 seconds.

START IN OPENING

This menu permits to select the functions of start during the
opening phase.
no
the command START is not available.
ChiU
the command START close the gate.
PAUS the command START stop the gate and goes into in
PAUSE.

START IN CLOSING

This menu permits to select the functions of start during the clo-
sing phase.
StoP
the command START stop the gate.
APEr
the command START open the gate

START IN PAUSE

This menu permits to select the functions of the command start
during the standstill.
ChiU
the command START closes the gate.
no
the command START is not available. This function cannot
be selected until the automatic closing has been activated
(menu Ch.AU).