Requirements for on-site installation
Lack of or insufficient residual-current circuit breaker.
Danger of fatal electric shock!
Installation of a class B all-current-sensitive residual-current circuit breaker with a trip current of
Danger
30 mA before the machine is put into operation for the first time.
* Considering the local conditions, the exact
dimensions must be determined.
The dimensions of the machine can be found
on page 1.
A
Waste water connection
EZ
Electrical connection
TWw
Fresh water connection
Installation diagram
PG 8164 AE RO, AE RO DOS / PG 8165 AE RO, AE RO DOS
1
Water inlet (max. 35 °C)
2
On-site water stop cock (provided by the customer)
3
Dirt trap (included in scope of delivery of the dishwasher)
4
Backflow preventer type EA (included in scope of delivery of the dishwasher)
For installations in Great Britain, a WRAS-approved backflow preventer of
type EC (Miele Mat.-Nr. 5794940) must be installed
5
Active charcoal filter (included in scope of delivery of the dishwasher)
6
Optional softener (increases the performance of the reverse osmosis module)
7
PG 8164 AE RO, AE RO DOS / PG 8165 AE RO, AE RO DOS
Page 3
Important!
Provide the local connections on the left or the
right beside the machine.
Observe both the local and country-specific
regulations when conducting electrical and
plumbing work.
Only when the local mains disconnector is
switched off, is the machine without power.
Involve the machine in equipotential bonding.
Inlet hose
New hoses supplied with the appliance are to be
used and old existing hoses may not be re-used.
The inlet hose must not be shortened or
damaged.
Electrical supply cable (Type H07 RN-F)
If the mains cable of this machine is damaged, it
must be replaced by a Miele approved technician
or its service agent or similar qualified person in
order to prevent hazards.
English
Note: These models and
accessories are not
available in all countries.
M.-Nr. 10416211; 09.05.2017; msch; 89013841-en
Subject to technical alterations