9. Specifications
9. Specifications
General data
Measurement accuracy
Mounting position
Visual indication of the
switching status
Design data
Sensitivity
Medium temperature
Models OLS-C01, OLS-C02
Models OLS-C04, OLS-F1
Model OLS-C05
Model OLS-5200
Ambient temperature
Models OLS-C01, OLS-C02,
OLS-F1
Model OLS-C04
Models OLS-C05, OLS-5200
Operating pressure
WIKA operating instructions models OLS-C0x, OLS-F1, OLS-5200
±2 mm
as required
1 LED
Model OLS-C05: Only with trimmer option,
internal LED
Not available for models OLS-C02,
OLS-5200, OLS-F1
Preset for the detection of aqueous media
and oils
Model OLS-C04: Also for the detection of
refrigerants
-30 ... +100 °C
-40 ... +100 °C
-40 ... +170 °C
-40 ... +130 °C
-25 ... +70 °C
-30 ... +70 °C
-30 ... +80 °C
0 ... 25 bar [0 ... 2.5 MPa]
Model OLS-C04: 0 ... 40 bar [0 ... 4 MPa]
EN
17