Descargar Imprimir esta página

SSS Siedle SK 600-0 Manual De Instrucciones página 5

Ocultar thumbs Ver también para SK 600-0:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 11
English
Application
The Steel communication terminal
functional unit SK 600-0 is fitted
with a 26.5 cm touchpanel in
portrait format. The basic system
comprises a platform-independent
operating system on a modern pro-
cessor module. It can be used in the
In-Home bus or Access system.
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician.
When mounting, consider the
lighting conditions, as these can
affect the legibility of the panel.
• Direct backlight
• Direct sunlight
• Reflective surfaces
• Direct light sources such as spot-
lights
Note
• Avoid direct sunlight.
• Adhere to the admissible tempera-
ture range.
Installation
All installed functional units are
completely pre-assembled in the
Steel system. All that is necessary is
connection to the installation.
Address setting
If more than one door station with
an SK 600-... or DRM 612-... are
installed in one line in an In-Home
bus system, each of this devices
must be given its own address. The
rotary switch is located behind the
inspection shaft cover, which is
marked by a green dot. Once the
operator level has been lifted off,
all covers can be accessed from the
front. The address can be set from 1
to 8 and may only be used once in
any one system.
1 In-Home bus wiring diagram
a) A network cable must be laid
without fail from the door to the
distributor for programming.
b) Conductor length bus indoor
device – storey call button ERT max.
50 m.
Terminal assignment
In-Home-Bus
Tak
In-Home bus:
TbK
Video, camera branch
b
Power supply
c
12 V AC
bv
Supply Vario bus
cv
12 V AC
Da
Data cable
Db
Vario bus
+
Power supply for communi-
-
cation terminal 24 V DC
RJ45
For programming
2 Access wiring diagram
a) A network cable must be laid
without fail from the door to the
distributor for programming.
c) If door releases or gate control
systems are fitted and their con-
nected values do not correspond to
12 V AC/DC and min. 20 Ohm, then
either switching output 2 (ATLC ter-
minals 13/14 (output)) or switching
output 3 (ANG terminals 11/12/14
(output)) can be used as a potential-
free door release contact.
To use switching output 2 or 3 as a
potential-free door release contact,
you must configure the corre-
sponding ATLC switching output in
the Access administration interface.
Terminal assignment Access
S1
power supply
S2
and
S3
audio transmission
S4
D1
data transmission with digital
D2
call and Vario bus data trans-
mission
V1
Video signal
V2
(two-wire FBAS)
+
Power supply for communi-
-
cation terminal 24 V DC
RJ45
For programming
LAN
Connection to the network
Measurement points
The measurement points of the
functional units which are located
parallel to the terminals are acces-
sible when mounted. For measure-
ments, the test shaft cover must be
removed. After measuring, replace
the test shaft cover.
Exchanging the functional unit
The functional unit can be com-
pletely exchanged if required.
Modules may only be exchanged by
specialist personnel when the equip-
ment is not live, i.e. when discon-
nected from the mains.
• Release the operating panel using
the enclosed mounting key and take
it off.
• If the functional unit cannot be
accessed from the back, the support
system will have to be removed.
• Unscrew the functional unit from
the back of the support plate and
pull out the connecting plug.
• Exchange the functional unit and
restore the plug connections.
• Carry out a function check
• Place the operating panel on the
mounting panel and lock using the
mounting key.
Specifications
Operating voltage: 24 V DC
Operating current: 920 mA
Protection system: IP 65
Ambient temperature:
–20 °C to +55 °C
Dimensions (mm) W x H x D:
338 x 223 x 40
5

Publicidad

loading