Metabo HPT NT 50A5 Instrucciones Y Manual De Seguridad página 20

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

English
Maintenance chart
ACTION
Drain air line fi lter daily.
Keep lubricator fi lled.
Clean fi lter element — then blow air
through fi lter in direction opposite to
normal fl ow.
Clean magazine and feeder
mechanism.
Keep push lever working properly.
Lubricate the Nailer after nailing.
Drain air compressor.
20
WHY
Prevent accumulation of moisture
and dirt.
Keep the Nailer lubricated.
Prevent clogging of fi lter with dirt.
Prevent a jam.
Promote operator safety and effi cient
Nailer operation.
Extend the Nailer life.
Keep the Nailer operated properly.
HOW
Open manual petcock.
Fill with metabo HPT pneumatic tool
lubricant.
Follow manufacturer's instructions.
Blow clean daily.
Blow clean daily.
Supply 5 – 10 drops of lubricant into
the Nailer.
Open petcock on air compressor
tank.

Publicidad

Tabla de contenido
loading