Type designation of fuses
Wöhner
16 A 31567
20 A 31568
30 A 31569*
*Required only for motors with high starting current profile
N-Note: The listed fuses provide optimum short-circuit protection and can reliably handle
the motor starting currents. We recommend using only these fuse types.
8. Application examples
Safe switch-off for multiple MOTUS
Emergency stop for multiple MOTUS
EN+ and EN-
The enable inputs are switched off via a safety relay as soon as an emergency stop
button is pressed. If the switch-off is performed, for instance, from a "safety controller"
with semiconductor outputs, the residual voltage must be < 5 V DC. Power interruptions
≤ 3 ms or voltage pulses ≤ 4 ms are filtered.
Revision 1, dated 01/2021
Phoenix Contact
16 A 2903126
20 A 2903384
30 A 2903119*
®
IO-Link devices
®
IO-Link devices, dual-channel switch-off via
Mersen
16 A FR10GR69V 16
20 A FR10GR69V 20
30 A CCMR30*