ance with operating temperature lim-
its specified for the device.
3) The safety of the final installation
and compliance with all prescribed
Standards (EN 12453 - EN 12445) is
the responsibility of the person who
assembles the various parts to con-
struct a total closing.
4) Use safety devices capable of moni-
toring the status of their connection to
the electrical control unit.
5) Once installation is finished, it is rec-
ommended that all necessary checks
be performed (appropriate program-
ming of the control panel and cor-
rect installation of safety devices) to
ensure that compliant installation has
been performed.
6) Fix the control unit to a wall, using the
relevant support which is fitted to the
casing, in such a way as to leave said
support facing downwards and insert
the fixing screws in the special holes.
7) The control unit does not have any
type of isolating device for the 230
Vac line. It is therefore the respon-
sibility of the installer to set up an
isolating device inside the system. It
is necessary to install an omnipolar
switch, surge category III. It must be
positioned to provide protection from
accidental closing, pursuant to point
5.2.9 of EN 12453.
8) Cables for power and connection to
the motor suitable for insertion in
the pg9 cable glands provided must
have an outside diameter between
4.5 and 7 mm. The internal conductors
wires must have a nominal section of
0.75mm
. If a raceway is not used, use
2
10