H05RR-F cables. Pay careful attention
when fastening the cables so that
they are anchored in a stable manner.
Furthermore, care is required when drill-
ing holes in the outside casing where
connecting and power supply cables will
pass, and when assembling the cable
glands, so that everything is installed so
as to maintain the panel's IP protection
characteristics.
9) The gear motor used to move the frame
must comply with the requirements of
point 5.2.7 of EN 12453.
10) In compliance with 5.4.2 of EN 12453,
it is recommended to use gear motors
equipped with an electrical-mechanical
release device, so that the frame can be
moved manually in case of necessity.
11) In compliance with 5.4.3. of EN 12453,
use electrical-mechanical release sys-
tems or similar devices which stop the
frame safely in the end run position.
12) The various electrical components
external to the control unit must be
cabled in accordance with standard EN
60204-1 as amended, and as set forth
in point 5.2.7 of EN 12453. The power
and connection cables must be secured
through the use of cable glands sup-
plied.
13) The assembly of a push button panel
for manual control must be completed
positioning the push button panel in
such a way that the user is not placed
in a dangerous position.
14) For proper functioning of the radio
receiver, if using one or more control
units, the installation at a minimum dis-
tance of at least 3 metres one from the
other is recommended.
11