Operation with different radio control models:
Different radio control models can be programmed: store one code (1 key) for Step-by-
Step cyclic operation (Opening - Stop - Closing); store two different codes (2 keys) for
separate controls, the first for Opening and the second for Closing; store one code (3
"BeFree series" keys) for three separate controls, the first for
Opening, the second for Stop and the third for Closing.
Radio control operation with 1 Key:
Using the radio control with only one key, the following function is obtained: the first
impulse commands Opening until the motor time expires. The second impulse commands
Closing of the frame. If an impulse occurs before the motor time expires, the control
unit stops the frame. A further impulse implements the re-starting of the motion in the
opposite direction.
Radio control operation with 2 Keys:
Using the radio control with 2 keys, the following function is obtained: the first key ("Up"
associated to the Opening direction) commands Opening until the motor time expires,
and the second key ("Down" associated to the Closing direction) commands Closing of
the frame. If the Up command is given again during Opening, the control unit continues
the Opening motion, while if a Down command is given, the control unit stops motion.
The same procedure is valid during the Closing phase.
Radio control operation with 3 Keys (BeFree series):
Using the BeFree, series radio controls, the following function is obtained: the Up key commands
Opening until the motor time expires, the Stop key commands Stop, and the Down key commands
Closing of the frame. If during opening or closing a Stop command is given, the control unit com-
mands the frame to stop. If during opening or closing the command opposite the present motion
is given, the control unit commands to run in the opposite direction.
PROGRAMMING:
SEL key: selects the type of function to be stored, selection is indicated by a flashing LED.
Repeatedly press the key to select the desired function. The selection remains active for
10 seconds, (indicated by the flashing LED); after 10 seconds, the control unit returns to
its original status.
The SET key: This programs the information according to the type of function previously
selected with the SEL button. IMPORTANT: The function of the SET key can be replaced
with the radio control, if programmed previously (CODE led on).
MAIN MENU
The control unit is supplied by the manufacturer with the possibility of selecting a number of
important functions.
————————————
Led Reference
Led off
1) CODE
No code
2) T. MOT.
Motor time 40 sec.
1) CODE : (Programming the Radio controls)
The control unit can store up to 120 different Radio Controls.
Programming the radio control with 1 or 2 Keys.
The radio control transmission codes are programmed as follows: press the SEL key, the
CODE LED will start flashing, at the same time send the first radio control code ("Up"
associated to the Opening direction); now the CODE LED will start flashing rapidly, send
the second code ("Down" associated to the Closing direction) to be stored, the CODE LED
will remain on and programming will be complete. If the second code is not sent within
10 seconds the control unit will exit the programming phase and select the function with
only one key of the radio control.
Programming the "BeFree Series" radio control with 3 Keys.
The control unit can store the whole "BeFree" radio control by programming only the
UP Key.
The "BeFree" radio control codes are programmed as follows: press the SEL key, the
CODE LED will start flashing, at the same time press the UP key of the desired radio
control; the CODE LED will remain on and programming will be complete.
Deletion:
All the stored devices are deleted as follows: press the SEL key, the CODE LED will start
flashing, then press the SET key for a few seconds, the CODE LED will turn off and the
codes are deleted.
Device already stored or not compatible warning:
The control unit can store up to 120 devices with different codes. If the user attempts to
perform the programming procedure for a device which is already stored in the memory
or which is not compatible, the CODE LED will start flashing rapidly for a few moments to
indicate that this procedure cannot be performed. The unit then returns to the program-
ming phase once again.
Maximum number of devices that can be stored :
The control unit can store up to 120 devices with different codes. If the maximum number
of devices has been reached and a programming process started, the control unit will
indicate that it has failed by flashing all the LEDs except the CODE LED which will remain
lit and steady. After 10 seconds the control unit exits programming mode.
13
MAIN MENU
—————————————
Led On
Code entered
Programmed time