Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57

Test mode

General remarks
Do not connect the charger to the mains supply during testing. In all tests, the charger
draws its supply from the battery being tested.
Once the charger has been connected to the battery, the following test phases run
automatically in sequence:
-
-
-
Testing the
The charger measures the open circuit voltage of the battery. If the battery was not used
battery open
for at least two hours, then this is referred to as open circuit voltage.
circuit voltage
1.
2.
3.
4.
5.
Testing battery
6.
startability
7.
8.
9.
If there is no starting procedure after 30 seconds, the charger changes over automatical-
ly to the alternator test. If the starting procedure is not possible, charge (or check) the
battery.
Warning! Risk of injury and damage from exposed, rotating vehicle parts.
When working in the vehicle's engine compartment, take care that hands, hair,
items of clothing and charger leads do not come into contact with moving parts,
e.g. fan belt, fan, etc.
Battery open circuit voltage test
Battery startability test (only on chargers for motor vehicle applications)
Alternator test (only on chargers for motor vehicle applications)
Note! All battery and generator test results are for information only and may
differ from the actual values. The charger checks the entire system. The results
are therefore to be seen as recommendations only.
Switch off engine and ignition, shed all loads
Establish connection to battery
All display elements on the display are activated. Depending on the type of charger,
the respective voltage(s) and/or symbol for the type of battery are displayed.
Charger measures battery open circuit voltage
Charger displays battery open circuit voltage for 15 seconds
100%
Battery ready for use
After the open circuit voltage test, the charger switches automatically to the startabi-
lity test and awaits the start procedure
Start engine
Charger checks battery voltage response during the starting procedure
Charger displays battery startability for 15 seconds
very good starting response
80%
50%
Charge battery
3
20%
0%
poor starting response

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Acctiva easy basic0510 955 6000510 955 605 basic

Tabla de contenido