GROUP 4 : TIMES
4.0 Pump stop
delay
4.0 sec
4.1Autom. Reset
Time
30 min
attempt is successful, Nettuno will automatically exit from the error condition and the system resumes normal
operation; if this is not the case, another attempt will be carried out after the same time interval. The maximum
settable interval is 240 minutes (recommended value is 30 min)
4.2 Autom.
reset tests
4.3 Reset all
Errors
ADVANCED PARAMETERS:
The advanced parameters are accessible only to the technical assistance service. For access to these parameters, it is
necessary to contact the re-seller, a technical assistance centre or the manufacturer.
The following table lists the advanced parameters for reference when technical assistance is required.
REF.
PARAMETER
7.0
Vboost
7.1
Dry run delay
7.2
Max.
hour
7.3
Anti-seizure protection
7.4
Dead time
7.5
Int. constant (Ki)
7.6
Prop. constant (Kp)
8.0
Last error recorded
8.1
Power supply timer
8.2
Motor timer
8.3
Motor start-ups
8.4
Rel. Software
9.0
Max. amb. temp.
9.1
Max. mod. temp.
4.0 – Pump stop delay: defines the delay before stopping the pump when
the pressure is the same as the set point and the frequency is below the stop
frequency
.
4.1 – Automatic reset time: if a temporary absence of water on intake is
detected during operation of the electric pump, Nettuno will shut off power
to the motor to avoid it being damaged. On this screen it is possible to set
how many minutes the device will remain stopped before carrying out an
automatic restart to check for the availability of water on intake. If the
4.2 - Automatic reset test no.: this parameter sets the number of attempts
that Nettuno will perform to resolve a stop condition due to dry running.
Once this limit has been exceeded, the system shuts down and the user's
5
intervention is required. If this value is set to zero, the auto-reset function is
switched off. The maximum number of attempts allowed is 20
4.3 - Total automatic reset: when set to ON, the automatic reset function
is active for any error, in addition to dry-running, detected by the system.
Caution: the automatic and uncontrolled reset of some errors (for example,
overload) could over time cause damage to the system and to Nettuno.
OFF
Always take great care when using this function.
DESCRIPTION
Voltage boost at 0Hz
Time delay before activation of the
protection due to lack of water
start-ups
per
Activation or deactivation of the control
on the number of start-ups per hour (leak
checks)
Activation or deactivation of the control
that enables start-up of the pump after 24
hours of downtime.
Dead time PWM setting
PID controller integrative constant
PID controller proportional constant
Last error occurred log
Inverter power supply time
Electric pump operation time
Pump start-up counter
Release of software
Maximum ambient temperature
IGBT module maximum temperature
.
.
46
.
DEFAULT SETTING
5%
30
OFF
OFF
20*125ns
10
15
0
0
0
0
/
80
85