Technical data
Voltage range
LEDs
Tolerance
Voltage detection
Polarity detection
Range detection
Response time
Frequency range
Automatic load (RCD/FI) Yes
Internal base load
Peak current
ON time
Single-pole phase test
Voltage range
Frequency range
Continuity test
Resistance range
Testing current
Overvoltage protection
Indication of rotating field direction
Voltage range (LEDs)
Frequency range
Measuring principle
Power supply
Power consumption
Operating conditions
Storage conditions
Overvoltage category
Pollution degree
Degree of protection
Weight
Test standards
Subject to technical alterations. 18W48
ActiveMaster
12, 24, 36, 50, 120, 230,
400, 690 V AC/DC
± 12, 24, 36, 50, 120, 230, 400,
690 V AC/DC
-30% to 0% of the reading
Automatic
Entire range
Automatic
< 0.1 s, LED
50/60 Hz
Approx. 2.1 W at 600 V
1s < 0.2 A / Is (5 s) < 3.5 mA
ON time = 30 s/10 min.
100 to 690 V AC
50/60 Hz
< 300 Ω
5 μA
690 V AC/DC
100 to 400 V
50/60 Hz
Two-pole with contact electrode
2x 1.5 Type AAA, LR03, alkaline
Max. 30 mA / approx. 250 mW
-10°C ... 55°C, Max. humidity
85%rH, no condensation,
Max. working altitude 2000 m
above sea level
-10°C ... 70°C, Max. humidity
80%rH
CAT II 1000 V
with protective cover:
CAT III - 1000 V / CAT IV 600 V
2
IP64
220 g
EN 61243-3; EN 61326
15
EN