Discharge Connection - EHEIM PowerLine 2048 Manual Del Usuario

Ocultar thumbs Ver también para PowerLine 2048:
Tabla de contenido

Publicidad

It is imperative to disconnect the filter from the mains prior to opening it.
The connecting line of this device can not be replaced. When the line is da-
maged, the device must no longer be used. Contact your specialised dealer
or your EHEIM Service Centre.
This equipment is not intended for use by persons (including children) with
limited physical, sensory or mental abilities or for persons with no experi-
ence or knowledge unless they are supervised by a person responsible for
safety or unless they have received from such a person instructions on how
to use the equipment. Children should be supervised to ensure that they do
not play with the equipment.
Notice: These devices produce magnetic fields which might
20 cm
cause electronic and mechanical disturbances or damages. This
also refers to pacemakers. Please consult the manuals of medical equip-
ment for the required safety margins.
Attention: Maintenance work presents the risk of crushing the fingers due to
high magnetic forces.
For your own safety, we recommend to form a drip loop
with the connection cable to prevent any water running
along the cable from intruding into the socket. When
using a multiple socket or an external power supply
unit, position them atop the filter's power connection.
Take the necessary precautions when handling components that can dis-
charge static electricity.
Do not clean the unit – or parts of it – in the dishwater. Not dishwater resi-
stant!
Do not dispose of this product as normal household waste. Take it to your
local refuse collection side.
The product is qualified in
accordance with the respective
national regulations and guidelines
and meets EC standards.
Model: see type plate on pump housing
Function
A
Pump
Filter module with cartridge
Diffusor
tom
Closing slide
Installation
B
Clip clamping plug into apertures in retaining plate. Install suction
pads. If preferred, the retaining plate can be attached to one side of the
pump, permitting the filter to be installed facing in any direction.
C / D Screw in either discharge connection (C) or diffusor (D) as required.
Discharge connection: used fo good water surface movement. Height
of filter is regulated by means of perforated locking device on mount-
ing support. Diffusor: This is preferable for aquariums without plants.
The oxygen supply can be regulated by the air regulating valve.
Open filter shutter and secure filter in aquarium (for minimum immer-
sion depth, see diagram C). Connect electrical plug to initiate filter
operation.
Internal filter 2048
Air regulating valve
Clamping plug
geprüfte
Sicherheit

Discharge connection

Retaining plate
Filter bot-
Suction cup.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Powerline 2002048020

Tabla de contenido