Installation instructions

EN Surge protection device

Item no.
Type
5095 364
V20-0-280
5095 161
V20-1-280
5095 162
V20-2-280
5095 163
V20-3-280
5095 164
V20-4-280
5095 251
V20-1+NPE-280
5095 252
V20-2+NPE-280
5095 253
V20-3+NPE-280
5095 281
V20-1+FS-280
5095 282
V20-2+FS-280
5095 283
V20-3+FS-280
5095 284
V20-4+FS-280
5095 331 V20-1+NPE+FS-280 Single-pole with NPE and FS
5095 332 V20-2+NPE+FS-280 Two-pole with NPE and FS
5095 333 V20-3+NPE+FS-280 Three-pole with NPE and FS
5095 600
C20-0-255
*
Figure
1

Product description

Surge protective device for equipotential bonding
of power supply systems according to VDE 0100-
443 (IEC 60364-4-44). For mounting on hat rails
and use in distributor housings. Arresters (Figure
) can be connected individually and are en-
1
coded on the rear side, in order to avoid incorrect
connection. They possess a thermodynamic cut-
off unit and have an arresting capacity of up to 40
kA (8/20) per pole.
If there is an error, the visual display switches
from green (grey) to red (Figure
With snap-on hat rail bracket (Figure
The spark gap C20-0-255 is intended as an ar-
rester between the neutral conductor N and the
protective conductor (PE conductor).
Only V20-..+FS..: With module for remote sig-
nalling through potential-free changeover contact
(Figure
).

Target group

The device may only be mounted and connected
by an electrical technician.
OBO Bettermann GmbH & Co. KG
Product
Single arrester*
Single pole
Two-pole
Three-pole
Four-pole
Single-pole with NPE
Two-pole with NPE
Three-pole with NPE
Single-pole with FS
Two-pole with FS
Three-pole with FS
Four-pole with FS
Single arrester*

General safety information

• Before working on power cables, ensure that
• Do not carry out mounting work during a storm!
• Comply with national laws and standards, e.g.

Mounting and installation

The device can be installed in any position (e.g.
vertical or horizontal).
).
Figure
).
specifies that,
2
– in the case of single-branch wiring,
– or, in the case of V wiring,
should never exceed 0.5 m.
For V wiring, use the connection terminal, item
no. 5012 010.
Protection path
I
Total
L – PE/N
L – PE/N
80 kA < 250 μA
L – PE/N
120 kA < 50 μA
L – PE, N – PE 160 kA < 50 μA
L – N, N – PE
60 kA
L – N, N – PE
60 kA
L – N, N – PE
60 kA
L – PE/N
L – PE/N
80 kA < 250 μA
L – PE/N
120 kA < 50 μA
L – PE, N – PE 160 kA < 50 μA
L – N, N – PE
60 kA
L – N, N – PE
60 kA
L – N, N – PE
60 kA
they are de-energised and secure them against
unintentional switch-on!
VDE 0100-534 (IEC 60364-5-53)!
: VDE 0100-534 (IEC 60364-5-53)
connection length a + b
length c
Caution! Risk of overloading!
The connection terminal 5012 010 is
approved for a maximum current load
≤ 50 A.
Use a suitable back-up fuse!
V20-...-280
Circuit
EN
I
diagram
PE
Figure
< 250 μA
1
2
3
4
< 2 μA
5
< 2 μA
6
< 2 μA
7
< 250 μA
1
2
3
4
< 2 μA
5
< 2 μA
6
< 2 μA
7
the total
1
the connection
2
8