MAINTENANCE - MANUTENTIÓN - MANTENIMIENTO
Fig. 27
Fig. 28
1/4"
[6 mm]
FilTerS CleAninG And/or SuBSTiTuTion
Iflittlewaterissuppliedbythemixeritisappropriatetochecktheconditionsoffilterspositionedonthe
wall connections behind the body of shower column. Before this operation make sure that water net-
work is off.
Loosentheconnectionsonwhichfiltersarepositioned.Keeponwithcleaningoperationsusingrunning
water to remove impurities. Verify that also the seats were clean from impurities or limestone.
Finally,followingtheoppositesequence,placefiltersintheirseatsandcheckthatallworksproperly.
nB. Iffiltersaredamagedtheycanbereplacedaccordingtotheabovedescription.
neTToyAGe eT/ou SuBSTiTuTion deS FilTreS
Danslecasoùilseproduiraitunefaibleperted'eausurlemélangeurilestopportundevérifierlacon-
ditiondesfiltresplacéssurlesraccordsàparoidisposésderrièrelecorpsdelacolonnedouche.Avant
d'effectuer cette opération s'assurer que l'alimentation du réseau hydrique est coupée.
Dévisserlesraccordssurlesquelssontmontéslesfiltres.Procéderauxopérationsdenettoyageen
utilisant l'eau courante pour éliminer les impuretés. Vérifier également que les bases soient nettoyées
de toutes impuretées ou calcaire.
Enfin,ensuivantlaprocédureinverse,mettrelesfiltresdansleurspropreslogementsetvérifierque
tout fonctionne correctement.
nB.Aucasoùl'onobserveraitunendommagementdesfiltresilestpossibled'endemanderlasubsti-
tutionetdeprocéderàleurremplacement