5. Insert new blade (I) Fig. 26, into the upper blade holder (J)
making certain the blade teeth are pointing down toward
the table. Push upper blade chuck locking lever (L) to the
front. Insert new blade into the lower blade holder Fig. 25
in the same manner.
6. Apply blade tension by referring to the following section
"ADJUSTINg BLADE TENSION."

FUSE REPLACEMENT

WARNINg: Disconnect machine from power source.
A fuse holder (A) Fig. 27, and fuse (B) are located at the rear
of the machine and should be removed and checked if the
machine does not operate. If the fuse (B) is bad, replace it
with a 3 amp fast blow fuse.
LUBRICATION
WARNINg: Disconnect machine from power source.
Perform maintenance below after each 20 hours of use.
1. Tilt the table 45° to the left as shown in Fig. 28.
2. Remove four rubber grommets (A) Fig. 29 that cover the
lubrication access holes.
3. Lubricate the pivot points in each of the four access
holes with a few drops of light machine oil.
4. Reassemble the four grommets as shown in Fig. 29.
5. Apply lightweight grease or anti-seize to lubricate the
tensioning lever (C) Fig. 21 where it pivots on the upper
chuck.
Fig. 26
Fig. 27
Fig. 28
17
L
B
A
A
J
I
Fig. 29