INSTRUCTIONS FOR USE - DIRECTIONS FOR INSTALLATION
Thanks to the high-power performance of its built-in microprocessor, this control unit for barriers offers a wide number
of services and adjustments. In addition, electronic power control guarantees a high safety level. A sophisticated
electronic control constantly monitors the power circuit and cuts off the unit when problems arise which reduce the
operating efficiency of the electronic clutch.
The main settings and operating modes can be defined using dip-switches while time and motor power adjustments
are performed using the trimmers installed on the electronic circuit board.
6 built-in LEDS constantly display the status of inputs / outputs in addition to any circuit malfunctions.
Power supply
Absorbed power
Max. motor load
Max. load on accessories
Ambient temperature
Protection fuses
Operating logic
Opening /closing time
Pause time
Thrust force
Peak time
Reversal time
Closing and opening slowdown time
Terminal board inputs
Radio control connector
Module connector
Terminal board outputs
Functions selected with dip-switches
3.1
TERMINAL BOARD M1
3.1.1 Network
Terminals "17-18" (Neutral - Phase), Power supply voltage 230 V~ - 50/60 Hz.
WARNING: the "GROUND" terminal must be connected to ground to ensure proper unit operation.
3.1.2 Flashing light
Terminals "15-16" (Phase - Neutral). Use a flasher with an operating voltage of 230 V~.
3.2
TERMINAL BOARD M2
3.2.1 Gear unit
Terminals "12-13-14" (Open - Common - Close). WARNING: if the gear unit is incorrectly connected or the connection
is not completed, the gear unit will be inhibited and this status will be indicated by the fast flashing WORK LED.
Notes:
1)
To install electric cables, us adequate rigid and/or flexible tubes.
2)
Always separate the low-voltage connection cables from the 230V~ power supply cables. Cables for the power
supply to the equipment must have a 1.5 mm
CONTROL BOARD FOR BARRIERS

1. GENERAL FEATURES

2. TECHNICAL FEATURES

3. CONNECTIONS - DESCRIPTION
section. To avoid interference, us separate sheathes.
2
5
230 V~ (+6 -10%) - 50/60 Hz.
550 W
500 W
24Vdc 500 mA
-20°C +50°C
2
Step-step/Automatic
30 sec. fixed
Adjustable using trimmer (from 2 to 90 sec.)
Adjustable using trimmer
1 sec. fixed
2 sec. fixed
1 sec. fixed
Total opening / Closing photocells /
Opening-closing limit switch / STOP /
Network power supply + Ground
Radio receiver boards
Motor control module
Accessory power supply 24 Vdc
/ Flasher / Motor
Operating modes
Closing photocell reaction