7.2 ELECTRONIC CLUTCH
To adjust the anti-crushing system tripping threshold use the "POWER" trimmer.
It is recommend to calibrate this torque to meet current standards.
STEP- STEP LOGIC
With each pulse only one status: Open - Stop - Close - Stop, etc.
Change in progress, with two seconds of pause for each reversal
AUTOMATIC LOGIC
Closes again after the pause time
Excluded
CLOSING PHOTOCELL OPERATION
When closing stops and reverses, when closed blocks START, while opening
stops and when disabled, starts
Stops and reverses the motion
PARK FUNCTION
Detects no START pulses during opening, repeats pause time if
in pause
Excluded
Note: all the adjustments are performed with the control unit turned off and the barrier closed.
BARRIER
STATUS
CLOSED
OPEN
CLOSING
OPENING
STOPPED
CLOSED
OPEN
IN PAUSE
CLOSING
OPENING
STOPPED
8. ADJUSTMENTS WITH DIP-SWITCH SW1
9. OPERATING LOGIC
START
Opens
Re-closes
Stops operation or
reverses as per dip-sw 1
Stops operation or
reverses as per dip-sw 1 or
does not detect
pulses as per dip-sw 4
Starts motion again in
opposite direction
Opens, performs the pause
and closes again
Closes again immediately
or repeats pause time
as per dip-sw 4
Stops operation or
reverses as per dip-sw 1
Stops operation or
reverses as per dip-sw 1 or
does not detect pulses
as per dip-sw 4
Starts motion again in
opposite direction
PULSES
STOP
Blocks START
Blocks operation and
enters STOP mode
Blocks START
Blocks START
Blocks operation and
enters STOP mode
Blocks START
7
ENGLISH
1
2
3
ON
OFF
ON
OFF
ON
OFF
PHOTOCELLS
No effect or blocks START
as per dip-3
Stops and reverses
No effect or stops and
starts after disabled
as per dip-sw 3
No effect or blocks START
as per dip-3
Blocks START
After disabled
pause reset
Stops and reverses
No effect or stops and
starts after disabled
as per dip-sw 3
4
ON
OFF