Connecting The Power Supply; Securing The Refrigerator - Dometic 10 Serie Instrucciones De Montaje

Ocultar thumbs Ver también para 10 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
Installing the refrigerator
4.3

Connecting the power supply

A
NOTICE! Damage hazard
• The electrical installation and repairs may only be performed by a
specialist in accordance with the applicable national regulations and
standards.
• To avoid voltage loss and therefore a drop in performance, the cable
should be kept as short as possible and should not be interrupted if
possible. For this reason avoid additional switches, plugs or power
strips.
• Before connecting check whether the operating voltage and the bat-
tery voltage correspond (see type plate).
1. Determine the required cross section of the cable in relation to the cable length
according to fig. 5, page 6.
2. Connect the cables to the AMP connector of the refrigerator (fig. 6, page 6).
3. Connect the other ends of the cables to the
A
NOTICE! Damage hazard
• Make sure the polarity is correct.
• Fit the positive (+) cable with a 10 A fuse.
– as directly as possible
– rd (red): with a fuse protection (10 A) fitted to the positive (+) pole
– bk (black): to the negative (–) pole
4.4

Securing the refrigerator

A
NOTICE! Damage hazard
Only screw through the bushings provided, otherwise foamed compo-
nents, such as cables, can be damaged.
I
NOTE
• Attach the side walls or the attached strips so that the screws are
tight, even under increased loads (while driving).
• The refrigerator is designed to provide a regulated air flow. The man-
ufacturer does not recommend to leave additional space between
the refrigerator and the recess walls.
16
RC(S)(L)(D)10-Series
power supply:
12 Vg
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido