PSC9626
Pressure Controls for Steam, Air or (hot) Water
Introduction
The series P48 pressure controls are designed
as operating or high/low cut-out control on
steam, air or (hot) water applications. Also for
non-combustible gases which are not harmful to
the materials in contact with these mediums.
On steam applications a steam trap is
recommended (see Accessories).
Some models have been tested and approved
according to PED97/23EC Cat IV (see type
number selection table)
Description
The P48 series have been developed for special
applications where pressure must be controlled.
All models have an adjustable differential
depending on the range (see type number
selection table).The P48AAA-9110 and
P48AAA-9120 has the power element outside
the case.
All the models have phosphor bronze bellows
and brass pressure connections except the
P48AAA-9150. This model has a stainless steel
bellows and pressure connection and is provided
with a brass adapter
1
male.
Generous wiring space provided
Splash-proof enclosure (IP54)
SPDT contacts are provided as
standard on single pressure
control
Trip-free manual reset
© 2003 Johnson Controls Inc.
Code No. PD-P48-E
Series P48
/
"-18 NPT female to R3/8
4
Feature and Benefits
European Refrigeration Controls Catalogue
P48 Pressure Control for Steam, Air or (hot)
Easy wiring and maintenance
Can be used for indoor/outdoor applications
Can be wired for alarm functions
Override is not possible in the control
function.
Catalog Section 6
Product Bulletin P48
Issue 03/06/2003
Water
Catalogue Section 6

Publicidad

loading

Resumen de contenidos para Johnson Controls P48 Serie

  • Página 1 Can be used for indoor/outdoor applications SPDT contacts are provided as Can be wired for alarm functions standard on single pressure control Trip-free manual reset Override is not possible in the control function. © 2003 Johnson Controls Inc. Catalogue Section 6 Code No. PD-P48-E...
  • Página 2 3 - 12 P48AAA-9150 0.2 - 4 P48BEA-9120 Manual reset 4 - 16 P48BEA-9140 -0.2 - 10 1 - 4.5 P48AAA-9230 Note: 1 bar = 100 kPa ≈ 14.5 psi Catalogue Section 6 © 2003 Johnson Controls Inc. Code No. PD-P48-E...
  • Página 3 Fig. 7 Fig. 8 All ranges except 0 to 1 bar and 0.2 to 4 bar Ranges 0 to 1 bar and 0.2 to 4 bar A. R3/8 A. R3/8 © 2003 Johnson Controls Inc. Catalogue Section 6 Code No. PD-P48-E...
  • Página 4: Dimensions (Mm)

    3. Four mounting holes M4 (deep 6 mm) 4. Cable inlet grommet (cable range ø5 to ø13) 5. Power element see fig 1 and 2 6. Reset button (reset models only) Fig. 9 Catalogue Section 6 © 2003 Johnson Controls Inc. Code No. PD-P48-E...
  • Página 5 The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office or representative. Johnson Controls shall not be liable for damages resulting from misapplication or misuse of its products.
  • Página 6: Instruction Sheet

    PSC9736 DEUTSCH Wiring Raccordement Verdrahtung ENGLISH SHT045N600(003) Bedrading Cableado Cablaggio Cablagem Ledningar Jodotus READ THIS INSTRUCTION SHEET CAREFULLY BEFORE BITTE LESEN SIE DIESE ANWEISUNGEN VOR DER IN- Elektrisk installation Kabling Kαλωδίωση INSTALLING, RETAIN IT SAFELY FOR FUTURE REFER- STALLATION SORGFÄLTIG DURCH UND BEWAHREN SIE Zapojení...
  • Página 7 ESPAÑOL SVENSKA NORSK LEA DETENIDAMENTE ESTA HOJA DE INSTRUCCIONES ANTES DE LÄS NOGA DESSA INSTALLATIONSANVISNINGAR INNAN INSTALLA- LES DENNE VEILEDNINGEN GRUNDIG FØR INSTALLERING, OG GJEM REALIZAR LA INSTALACION Y GUARDELA PARA FUTURAS CON- TIONEN UTFÖRS OCH BEVARA DEM FÖR FRAMTIDA REFERENS. DEN FOR FREMTIDIG BRUK.

Este manual también es adecuado para:

P48aaa-9110P48aaa-9120P48bea-9120P48aaa-9150P48aaa-9130P48aaa-9140 ... Mostrar todo