Application
P70, P72, and P170 Series Controls for Low Pressure
Applications provide low-side pressure control on
commercial refrigeration and air-conditioning
applications.
IMPORTANT:
Use the P70, P72, and P170
Series Controls for Low Pressure Applications only
as an operating control. Where failure or malfunction
of a P70, P72, or P170 pressure control could lead
to personal injury or property damage to the
controlled equipment or other property, additional
precautions must be designed into the control
system. Incorporate and maintain other devices such
as supervisory or alarm systems or safety or limit
controls intended to warn of, or protect against,
failure or malfunction of the P70, P72, or P170
pressure control.
P70A and P170A type models with Single-Pole
Single-Throw (SPST) Open-Low switch action are the
most popular models and are typically used for
Open-Low operation and pump-down control.
P70 and P170 Series control models are also
available with SPST Open-High switch action and are
typically used for capacity control. Control models with
Single-Pole Double-Throw (SPDT) or 4-wire, 2-circuit
switch action allow users to install alarm devices or
other control circuits.
P72 Series control models have a Double-Pole
Single-Throw (DPST) switch with load-carrying
contacts that provide direct control of 208-240 VAC
single-phase motors up to 3 hp, 480 VAC
single-phase, non-compressor motors, and 208-220
VAC 3-phase motors up to 5 hp. See Table 6.
These controls are available in several pressure
ranges and are compatible with most common
refrigerants. They may also be used on air, water,
and other non-corrosive fluid applications.
Ammonia-compatible models are also available. See
Table 2.
The MICRO-SET® option provides fine adjustment of
the differential setting for precision pressure control of
critical low pressure applications.
© 2006 Johnson Controls, Inc.
Part No. 24-7664-1601, Rev. C
P70, P72, and P170 Series Controls for
Low Pressure Applications
Installation Instructions
Some models are available with Limited Knob
Adjustment, which restricts adjustment of the
pressure settings and deters overadjustment or
tampering. See Limited Knob Adjustment.
The Manual Reset Lockout mechanism does not
allow the control to automatically reset after the control
has Cutout, providing shutdown capability for
unmonitored equipment. See Manual Reset Operation.
NEMA 1 enclosures are standard on most models.
NEMA 3R enclosures are available on select models.
!
CAUTION: Risk of Property Damage.
Mount the pressure control separately from the
electrical cabinet and seal all electrical piping to
prevent ammonia from migrating to electrical
components. Where there may be exposure to
ammonia, use only ammonia compatible control
modules and pressure connections. System
shutdown due to improper adjustment may cause
property damage.
Dimensions
2-Mounting Holes
10-32 UNF-2B
Thread
3-1/4
83
5/16
8
1-7/8
48
3/16
Diameter
3/16
Mounting Hole
5
5
2-1/16
53
15/16
24
1-5/16
34
3-1/16
77
1/16
4
101
2
Figure 1: Dimensions of P70, P72, and P170
Pressure Controls with NEMA 1 Enclosures,
in. (mm)
Issue Date June 12, 2006
5/16
2-13/16
8
71
5/16
8
1
25
1-1/8
29
1-11/16
1-3/4
13/16
44
20
3/16
3/8
3/16
5
X
5
10
Diameter
Mounting Hole
1-1/4
33
(NEMA 1/2 in.)
7/8
22 Conduit Hole
www.johnsoncontrols.com
3-1/4
83
43
1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Johnson Controls P70 Serie

  • Página 1 1/16 the differential setting for precision pressure control of critical low pressure applications. Figure 1: Dimensions of P70, P72, and P170 Pressure Controls with NEMA 1 Enclosures, in. (mm) © 2006 Johnson Controls, Inc. Part No. 24-7664-1601, Rev. C www.johnsoncontrols.com...
  • Página 2: Pressure Connections

    IMPORTANT: Use only the mounting screws supplied with the Universal Mounting Bracket to avoid damaging internal components. Be careful not to distort or bend the control case when mounting the control to an uneven surface. Using other screws 4-1/16 or bending the control case will void the warranty. Mounting Holes for Flat Vertical Surfaces 4-1/16...
  • Página 3 Avoid Contact between the Capillary Tubing and IMPORTANT: Use only the terminal screws Sharp or Abrasive Objects that are supplied with the switch-block. Using other Vibration of sharp or abrasive objects in contact with screws may cause damage to the switch-block and capillary tubes can result in leaks.
  • Página 4 Table 1: Single Pressure Controls Switch Action, Low Events, High Events, Model Types, and Electrical Rating Table References Switch and Action Low Event High Event Model Types - Electrical Rating Table Reference Single-Pole Single-Throw Cutout Cut In P70A, P70B, P170A (SPST) Open-Low (Opens Line to M1) (Closes Line to M1)
  • Página 5 Figure 8: Adjusting P70, P72, and P170 Controls for Low Pressure Applications 3. Place the indicator plate, as shown in Figure 9, to Limited Knob Adjustment lock either the range screw or differential screw in Some models are supplied with a Limited Knob the desired setting.
  • Página 6 Manual Reset Operation n equipment with locked out controls, first determine and remedy the cause of the lockout, and allow the Pressure controls with the Manual Reset option lock sensed pressure to return to the Cut In setpoint. Then, out when they reach Cutout pressure and must be press and release the reset button on the front of the manually reset by the user to restart the controlled control to restore operation of the controlled...
  • Página 7 Electrical Ratings Table 3: SPST Electrical Ratings (P70A, B, C, D, and P170A, B, C, D Type Models) Standard Single-Phase Ratings Hermetic Compressor Single-Phase Ratings 120 VAC 208 VAC 240 VAC *480 VAC *600 VAC 208/240 VAC Motor Full-Load Amperes 18.7 Motor Locked-Rotor Amperes 112.2...
  • Página 8: Technical Specifications

    The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, contact Refrigeration Application Engineering at 1-800-275-5676. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products.
  • Página 9: Controles Para Aplicaciones De Baja Presión Series P70, P72, Y P170

    Controles para Aplicaciones de Baja Presión Series P70, P72, y P170 Aplicación Los Controles para Aplicaciones de Baja Presión de las equipo no monitoreado. Ver Ajuste de Operación de Series P70, P72, y P170 proporcionan control de presión Restablecimiento Manual. del lado bajo en aplicaciones de refrigeración comercial y Las cajas NEMA 1 son estándar en la mayoría de los de aire acondicionado.
  • Página 10: Instalación

    IMPORTANTE: Use sólo el tornillo de instalación proveído con el soporte de Instalación Universal para evitar daños a los componentes internos. No tuerza la caja de control cuando se instale el control en una superficie vertical irregular. 4-1/16 Orificios de Montaje para Superficies Planas y Verticales Utilice los tornillos de montaje provistos.
  • Página 11 No Apriete Demasiado las Tuercas Abocinadas en los Conectores de la Línea de Presión Carga Si aprieta las conexiones abocinadas demasiado puede dañar los hilos de las tuercas abocinadas o los conectores abocinados y puede resultar en fugas. No exceda 9 pies-lb (12 Nm) de torque cuando se aprieten las conexiones de latón abocinadas.
  • Página 12 Tabla 1: Controles de Presión Sencilla con Acción del Interruptor, Eventos Bajos, Eventos Altos, Tipos de Modelo, y Tabla de Referencia de Clasificación Eléctrica Tipos de Modelos – Tabla Interruptor y Acción Evento Bajo Evento Alto de Referencia de Clasificación Electrica Un Polo-Un Tiro (SPST) Desconexión Conexión...
  • Página 13: Ajuste De Perilla Limitado

    Paso 1. Establezca evento alto ajustando el tornillo de rango. Controles de Rango Universal : Gire el tornillo hacia la izquierda para incrementar evento alto. Controles MICRO-SET: Gire el tornillo hacia la izquierda para disminuir el punto de DESCONEXION. Indicador de Evento Alto ( Controles Todo Rango) Indicador de Evento Alto (Controles de Rango Universal) Indicador de CONEXION (Controles MICRO-SET) Indicador de CONEXION (Controles MICRO0-SET)
  • Página 14 Operación de Restablecimiento Manual En equipo con los controles bloqueados, determine y resuelve la razón del bloqueo, y permita que la presión Los controles de presión con la opción de detectada regrese al punto de ajuste de Conexión. Restablecimiento Manual se bloquean cuando se Después, presione y suelte el botón de restablecimiento alcanzan la presión de Desconexión y deben que se localiza al frente del control para restablecer la...
  • Página 15 Clasificaciones Eléctricas Tabla 3: Clasificaciones Eléctricas del Interruptor SPST (Tipos P70A, B, C, D, y P170A, B, C, D) Clasificaciones para Clasificaciones de Motores Monofásicos Estándares Compresor Hermético Monofásico 120 VCA 208 VCA 240 VCA *480 VCA *600 VCA 208/240 VCA Amperios del Motor con 18.7 Carga Completa...
  • Página 16: Especificaciones Técnicas

    Table 6: Clasificaciones Electricas para DPST (Tipos P72A, B, C y D) Rangos para Clasificaciones Estándares Compresor Hermético *480 *600 1Ø 1Ø 1Ø 3Ø 3Ø 1Ø 1Ø 1Ø 1Ø Amperios del Motor con Carga 18.7 15.9 Completa Amperios del Motor con el Rotor 112.2 95.4 28.8...

Este manual también es adecuado para:

P72 serieP170 serieP70aP170a

Tabla de contenido