2. Remove Bias Charge Roller (B) – iR-1600/2000 units only.
Clean the charge roller with charge roller cleaning wipe, or with clean deionized water and white Chicopee Chix Soft Cloth; dry wipe in one
direction only.
2
3. For iR-1600/2000 units only – remove white BCR support clip (C).
4. Remove Drum Cleaning Blade (D) by removing the two (2) securing
screws. Note the quantity and location of any blade shims that may
be present under the used blade, and save for reinstallation.
4
Rebuilding
5. Vacuum out waste toner, being careful not to damage the Mylar recovery blade.
6. Install any previously removed drum cleaning blade shims removed in disassembly, then install new drum cleaning blade, securing with the two
(2) screws removed in step 4. (NOTE: iR-1600/2000 - Install previously removed white BCR support clip.)
7. Reinstall clean BCR – iR-1600/2000 units only or
Install new BCR – iR-1210/1310 units only.
8. Apply light amount of Kynar to OPC drum. Install new OPC drum in cartridge securing it in place with drum holding pin removed in step 1.
(NOTE: iR-1600/2000 – Reinstall screw removed in step 1.) Rotate OPC drum one rotation down (counter) to the drum-cleaning blade. If Kynar
is visible on the BCR, dry wipe it with Chicopee Chix Soft Cloth to prevent copy quality issues.
iR-1210/1310 & iR-1600/2000
B
D
3
C
iR-1600/2000 Model Only