Allmatic BIOS2 ECO Guía Para La Instalación página 15

Ocultar thumbs Ver también para BIOS2 ECO:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4
5
6
7
8
9
10
11
12
13
CONNECTION OF RELAY CARD R2 (optional)
If the courtesy light is present, the functioning of
courtesy light/open gate lamp is controlled in the
.
.
FC
FC
Y Y Y Y
FC FC
advanced menu
Maximum load 230 Vac 5A, 30 Vdc 5A max.
Power supply
6-1622176
rev. 7
18/09/2020
ACCESSORIES OUTPUTS
Accessories output 24Vdc, to the clamps 11 e
and 12 of the control unit 6 W max.
OPENING PHOTOCELL INPUT
Connect the
NORMALLY CLOSED contact
of the photocell (PHOTO) between the clamps
13 and 20 of the control unit.
If not used set the DIP switch PH2 ON.
CLOSING PHOTOCELL INPUT
Connect the
NORMALLY CLOSED contact
of the photocell (PHOTO) between the clamps
14 and 20 of the control unit.
If not used set the DIP switch PH1 ON.
STOP INPUT
Connect the contact NORMALLY CLOSED of
the STOP between the clamps 15 and 20 of the
control unit.
OPEN INPUT
Connect the button OPEN between the clamps
16 and 20 of the control unit.
CLOSE INPUT
Connect the button CLOSE between the clamps
17 and 20 of the control unit.
PARTIAL OPENING INPUT
Connect the button PED between the clamps 18
and 20 of the control unit.
STEP BY STEP INPUT
Connect the button SS between the clamps 19
and 20 of the control unit.
ANTENNA
Connect the signal cable of the antenna to the
clamp 22 and the ground of the antenna to the
clamp 21 of the control unit.
Courtesy light
Open gate lamp
ITA
ENG
FRA
Functioning:
- Closing: Stops the movement and waits until the
beam is freed, then moves in opening
- Opening: stops the movement and waits until the
beam is freed, then moves in opening.
Functioning:
- Closing: immediate inversion of movement.
- Opening: no intervention during the movement.
If not used set the DIP switch STOP ON.
The presence of the metallic parts or humidity in the
walls could have negative influences on the range of
the system. We suggest therefore to not place the
receiving antenna and/or transmitters near big
metallic objects, near the floor or on the ground.
The contact for electrical lock is enabled with the
elm
elm
elm
elm
parameter in the advanced menu
Maximum load 230 Vac 5A, 30 Vdc 5A max.
Electrical lock
ESP
DEU
POR
Power supply
3 / 12

Publicidad

Tabla de contenido
loading

Tabla de contenido