CONTROL DESCRIPTIONS
The appliance is equipped with the
listed control devices, required to
run its main functions.
A) Timer: used to start the appli-
ance and set processing time.
B) Selector:
processing power level.
Low position: microwave operat-
ing mode with low power level
(17%).
Defrost position: microwave
operating mode with medium-
GB
low power level (33%).
Med position: microwave oper-
ating mode with medium power
level (55%).
Med-High position: microwave
operating mode with medium-low power level (77%).
High position: microwave operating mode with high power level (100%).
RECOMMENDATIONS FOR USE
1 - Based on the type of process (defrost, cook, heat, etc.) suitably prepare food product
and place it in an appropriate container.
Cover food product that may spray chamber walls during processing.
2 - Place the container in the processing chamber and close the door.
3 - Rotate the selector (A) (always clockwise) to select the required power level.
used
to
set
the
- 24 -
ME/1600 MICROWAVE
OVEN
B
A
IDM-34602000600.tif
English language