- GB -
− Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
− Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use.
− Ensure that the power connection cable cross section is not smaller than that of the rubber sheath with the
identification H05RN-F. Extension cables must meet DIN VDE 0620.
− Protect the plug connections from moisture.
− Only plug the unit into a correctly fitted socket.
Safe operation
− Never operate the unit if either the electrical cables or the housing are defective!
− Do not carry or pull the unit by its electrical cable.
− Route all cables such that damage is excluded and nobody can trip over them.
− Never open the unit housing or its attendant components, unless this is explicitly required in the operating
instructions.
− Only use original spare parts and accessories for the unit.
− Never carry out technical modifications to the unit.
− Only have repairs carried out by customer service points authorised by OASE.
− Keep the socket and power plug dry.
− Only operate the unit if no persons are in the water!
Aquarius Universal Eco 3000/4000:
− The power connection cables cannot be replaced. When the cable is damaged, the unit or the component needs to
be disposed of.
Important! The unit is equipped with a permanent magnet. The magnetic field may affect the function of pace-
makers.
Installation
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
The unit can be set up either submerged (A) or dry (B).
General preparatory work: Bolt on the suction unit (3) and fit the pressure socket (2). Connect the desired hose for the
water feature to the pressure socket. Adapt stepped hose connectors to the water supply and return in accordance with
the hose diameter (C). Remove the pump foot, if necessary. For this purpose, press the pump foot to the rear, as
illustrated (D)
Submerged installation (A)
Operation with the pre-filter fitted. Push the pre-filter over the suction unit and fasten the filter using the bayonet closu-
re. Place the unit in the water at the desired position. Ensure that the unit is fully submerged. Maximum installation
depth:4 metres.
Dry installation (B)
Bolt the suction unit on and turn the priming opening to an optimum position for priming and connecting the suction
hose. Connect the suction hose to the suction unit. Always position the unit below the water line to prevent dry running
and the intake of air when switching on and operating the unit. Risk of damage!
Never connect the unit to a water line.
Install the unit so that it is not exposed to direct sun radiation (max. 40 ºC).
Start-up
Attention! The pump must never run dry.
Possible consequence: The pump will be destroyed.
Protective measure: Check the water level at regular intervals. Always place the unit below water level.
8