7.Failures:

Problem
Motor does not start - No mains voltage
Magnet does not
work
Lubrication does
not work
info@bds-maschinen.de info@bds-maschinen.de info@bds-maschinen.de
Cause
- Fine-wire fuse defective
- Magnet not activated
- Direction of rotation not
selected
- Switch defective
- Magnet activated
- No mains voltage
- Fine-wire fuse defective
- Switch defective
- No lubricant available
- Cock closed
- Connecting nipple clogged
Remedy
- Check mains voltage
- Replace the fuse
- Activate the magnet
- Pre-select direction of rotation
- Have the switch replaced
- Activate the magnet
- Check mains voltage
- Replace the fuse
- Have the switch replaced
- Top-up lubricant
- Open the cock
- Clean the tank completely