button to select AC A or DC A mode.
Press
button > one second to return to
AUTO AC/DC A mode.
Press
button to enter Low Pass Filter
mode (LPF is displayed). Press a second time
to enter Inrush mode (INRUSH is displayed).
Press again to exit the function.
Press
button to activate non-contact
/
voltage mode. Press a second time to exit
non-contact voltage mode.
Press
/
button > two seconds to
clear DC A reading from the display ( is
displayed) and establish a baseline for DC A.
Press
button > two seconds again to exit
this mode.
1. ZERO mode can be activated in DC A and
DC A of Auto DC/AC A mode only.
2. When ZERO is activated (symbol
displayed in DC A and Auto DC A mode
only), the offset residual value will not be
reset until the Meter is turned OFF.
3. ZERO can be activated if residual value < 6
A in DC A mode, < 6 A DC and <0.1 A AC in
Auto DC/AC A mode.
HOLD
Press HOLD button to freeze the display
reading (HOLD is displayed) and releases the
reading when pressed a second time.