To reach the best performance, we recommend
to set the CVIL II controller parameters as
follows:
Type
of
Parameters
joint
Run down speed
target torque
Hard
Pulse amplitude
Run down speed
target torque
Soft
Pulse amplitude
Decrease
pre-tightening
speed by 10%
Decrease
pulse amplitude
by 10%
07/2014
%
20 30 40
%
40 70 70
%
100
%
100
Tighten your application
Final torque
target torque
Yes
Some pulses appear
No
on CVIPC or
are noise perceptible
Yes
too low
Number
of pulses
OK
Setup OK for the joint
17 / 128
Increase
No
pulse amplitude
by 10%
too high
Speed ≥ 100%
Yes
6159939060_07
Series: D
No
Increase
pre-tightening
speed by 10%
Increase
pulse amplitude
by 10%