Installation and User Manual
Installation and User Manual
Installation and User Manual
2.6 If the sauna heater will not heat up
If the sauna heater will not heat up, please check that:
- the power is on;
- the main fuses of the sauna heater are intact;
- is there any error messages on the control panel. In case of an error message on the control
panel, please refer to the control panel instructions.
THE PERSON INSTALLING THE SAUNA HEATER SHOULD LEAVE THESE INSTRUCTIONS AT THE PREMIS-
ES FOR THE FUTURE USER.
2.7 Preparing for sauna heater installation
Check the following before installing the sauna heater:
1. The ratio of the heater's input (kW) and the sauna room's volume (m
presented in Table 1 on page 8. The minimum and maximum volumes must not be exceeded.
2. The sauna room ceiling must be min 1900 mm high.
3. Uninsulated and masonry stone walls extend the preheating time. Each square metre of plastered ceiling or
wall surface adds 1.2 m
4. Check page 8 Table 2 section for a suitable fuse size (A) and the correct diameter of the power supply
cable (mm²) for the sauna heater in question.
5. Conform to the specified safety clearance around the sauna heater.
There should be enough room around the sauna heater for maintenance purposes, a doorway etc.
2.8 Installation
Follow the safety clearance specifications on page 8. when installing the sauna heater. Thin panel is not a suitable
mounting base. The mounting base must be reinforced with timber behind the panel. The minimum clearances
specified on page 8 table 1 must be followed also in case the sauna room wall materials are incombustible.
Walls or ceilings must not be clad with fibre-reinforced plaster board or other light-weight cladding, because they
may cause a fire hazard.
A single sauna heater is allowed per a sauna room.
1. Prepare installation holes for the heater wall mount,
Note the necessary safety distance, see table 1 on page 8.
Screw in the upper bolts, leave the head ca. 2mm off the wall.
The lower bolts are installed and tightened at the end.
2. Turn the heater upside down. The installation holes (4 pcs) for the
wall mounts are located in the bottom plate, see the arrows.
Ring Wall D
Havanna D
Havanna D
3
to the sauna room's volume.
3
). Volume/input recommendations are
6
6
6