Translation of the original instructions
The keypad is blocked by keeping
for a few seconds: "Loc" will appear on the display.
Pressing them once again will unblock the keypad: "UnL" will appear
on the display.
ON/STAND BY
Press this button for a few seconds to switch the appliance into
status ON or STAND BY.

MANUAL DEFROSTING

Press this button for a few seconds to activate manual defrosting, if
the temperature of the evaporator allows it and provided that the
Overcooling function is not activated.
If the defrosting time interval elapses while Overcooling is in
progress, the former will be activated upon conclusion of the latter.
CHAMBER LIGHT if parameter u1=0
Press the auxiliary button to switch the chamber light on and off
manually (only glass door version)
DOWN button
This scrolls the menu items and decreases the values.
When pressed for a few seconds, the Overcooling function is
activated unless defrosting or dripping is not in progress or the
evaporator fan is stopped.
During Overcooling, the working set point is decreased to the
temperature and for the time set by the parameters.
UP button
This scrolls the menu items and increases the values.
When pressed for a few seconds, the low RH% function ("rhL"
appears on the display) or the high RH% function ("rhH" appears on
the display) is activated for 10 seconds.
If the function is not available and the button is pressed, "----" will
appear on the display.
SET POINT
This provides access to the set point edit function.
Briefly press any button.
Press the SET ( ) button: the compressor LED will flash.
Press the UP ( ) or DOWN ( ) button within 15 seconds.
Press the SET ( ) button or do not operate for the compressor LED to
go off, after which the instrument will exit from the procedure.
DO NOT PERFORM ANY MAINTAINANCE WHEN THE
APPLIANCE IS IN ON OR STAND BY
DISCONNECT FROM ELECTRICAL POWER SUPPLY NET.
and
pressed simultaneously
LED
MEANING
ON: The compressor is on
FLASHING: The working Set Point is being changed
Compressor protection in progress
ON: Defrosting in progress
FLASHING
Defrosting requested but compressor protection is in progress
Dripping in progress; Heating coolant in progress
ON The evaporator fan is on
FLASHING The evaporator fan is being stopped
ON : Chamber light switched on manually
FLASHING Chamber light switched on automatically
ON
The anti-steaming up resistors will be switched on
Auxiliary output switched on manually
Alarm output activated
The door resistors will be switched on
The evaporator valve will be activated
FLASHING : Auxiliary output switched on remotely
ON Overcooling in progress
ON Alarm or error in progress
ON: Not all the information regarding the HACCP alarms has
been displayed
FLASHING : At least one new alarm has been saved
OFF : All the information regarding the alarms has been displayed
List of the HACCP alarms has been deleted
ON Energy Saving in progress
ON Compressor maintenance required
ON The temperature measurement unit will be degrees Celsius
ON The temperature measurement unit will be degrees Fahrenheit
ON: The instrument is on stand-by
CODE MEANING
rhL
Low RH% function selected
rhH
High RH% function selected
Loc
The keypad is blocked; The working Set Point is blocked
- - - -
Requested function is not available