Farfisa Alba CV2124AB Manual Del Usuario página 24

Ocultar thumbs Ver también para Alba CV2124AB:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
Block Address valid for all call buttons
(code 112)
To program the Block Address valid for all call
buttons (factory setting 000; block addresses
allowed between 000 and 099).
Enter code 112;
press button1/ to confirm;
enter the new Block Address valid for all call
buttons;
press button1/ to confirm;
continue with the next programming or exit
programming.
Sequential Device Addresses for all call
buttons (code 113)
To program with sequential Device Addresses
of all the call buttons in the external unit, you
must program the Device Address from button
1 of the audio-video module (factory setting
099; addresses allowed from 001 to 200);
the other buttons on the audio-video module
and any additional button modules will call
up sequential incremental Device Addresses
depending on the order they were connected.
To carry out the programming, you need to:
Enter code 113;
press button1/ to confirm;
enter the new Device Address to be assigned
to button 1 of the audio-video module;
press button1/ to confirm, the audio-video
module buttons and all the additional button
modules connected to it will automatically
assume a progressive incremental address
starting from the device address assigned
to button 1 (see examples below);
continue with the next programming or exit
programming.
Example: Block Address 004 and Device Ad-
dress of button P1 = 136, the following buttons
will call the following addresses:
Single-Button
A u d i o -V i d e o
Module
04-
04-
P1 - P1
136
136
04-
04-
P2 - P2
137
137
1 s t b u t t o n
04-
04-
P3 - P3
138
138
module
04-
04-
P4 - P4
139
139
04-
04-
P5 - P5
2nd button
140
140
module
04-
04-
P6 - P6
141
141
04-
04-
P7 - P7
142
142
04-
04-
P8 - P8
143
143
From 3rd to 8th button
module
- 24 -
Mi 2530/1
Double-Button
Audio-Video
Module
04-
04-
P3 - P1
138
136
04-
04-
P4 - P2
139
137
1 s t b u t t o n
04-
04-
P9 - P5
module
144
140
04-
04-
P10 - P6
145
141
04-
04-
P11 - P7
146
142
04-
04-
P12 - P8
147
143
2nd button
04-
04-
P17 - P13
module
152
148
04-
04-
P18 - P14
153
149
From 3rd to 8th button
module
Enable tone while electrical lock is opening
(code 121)
By enabling the function, the audio-video
module emits a notification tone for the entire
period for which the lock is activated.
Enter code 121;
press button1/ to confirm;
to enable the function enter the value 111;
to disable the function enter the value 222;
press button1/ to confirm;
continue with the next programming or exit
programming.
Turning OFF video signal while lock is opening
(code 122)
By enabling the function, the audio-video
module automatically turns OFF the video
signal for the entire period for which the lock
is activated. This function is used to optimise
the use of energy during lock opening.
Enter code 122;
press button1/ to confirm;
to enable the function enter the value 111;
to disable the function enter the value 222;
press button1/ to confirm;
continue with the next programming or exit
programming.
Enabling the activation of the auxiliary relay
with PB-GN contact (code 123)
By enabling this function when closing the
PB-GN contacts, instead of activating the elec-
trical lock (terminals S+ and S-), is activated
the auxiliary relay and contacts C and NO of
J13 will be closed.
Enter code 123;
press button1/ to confirm;
to enable the function enter the value 111;
to disable the function enter the value 222;
press button1/ to confirm;
continue with the next programming or exit
programming.
Sending warning code "door is opened" (code
124)
After enabling this function when closing the
PB-GN contacts, the audio-video module, in-
stead of activating the electric lock connected
to the S+ and S- terminals, transmits on BUS
DUO the "door is opened" warning code; discon-
necting the contacts, the audio-video module
sends the "door is closed" code.
To enable this function you need to:
enter code 124;
press button1/ to confirm;
to enable the function enter the value 111;
to disable the function enter the value 222;
press button1/ to confirm;
continue with the next programming or exit
programming.
Attention: If the warning code is to be
displayed on EX362/EX3262C, mode 7
must be enabled on them (see the relevant
instruction manuals);
Maximum talk time 8 minutes (code 128)
By enabling this function, the maximum talk
time increases from 1.5 minutes (factory value)
to 8 minutes.
Enter code 128;
press button1/ to confirm;
to enable the function enter the value 111;
to disable the function enter the value 222;
press button1/ to confirm;
continue with the next programming or exit
programming.
Electrical Lock opening time (code 131)
The lock opening time can be varied as follows:
enter code 131;
press button1/ to confirm;
enter the new activation time (factory set-
ting 1 sec; allowed values 001-009 sec.);
press button1/ to confirm;
continue with the next programming or exit
programming.
Auxiliary relay activation time (code 132)
The activation time of the auxiliary relay can
be varied as follows:
enter code 132;
press button1/ to confirm;
enter the new activation time (factory set-
ting 3 sec; allowed values 000-099 sec.);
Attention: saving time as 000 the relay
acts as a bistable;
press button1/ to confirm;
continue with the next programming or exit
programming.
Presence of door keeper exchangers
(code 142)
The door station must be suitably programmed
depending on whether it should send calls
directly to the users or to a main or secondary
door keeper exchanger; to carry out the pro-
gramming it is necessary to store the address
201 if the door station has to call main door
keeper exchangers or 210 if the door station
has t o call secondary door keeper exchangers.
The 255 value indicates that no door keeper
exchanger is present and calls are sent directly
to the users. To run the programming:
enter code 142;
press button1/ to confirm;
enter the address 201, 210 or 255 (factory
setting 255=no door keeper exchanger;
allowed values 201 to send calls to main
door keeper exchangers, 210 to send calls
to secondary door keeper exchangers or 255
to send calls directly to the users);
press button1/ to confirm;

Publicidad