c- Press simultaneously on the UP and DOWN buttons of a Hz transmitter. The motor turns 0.5 second in one direction, then in the
other.
This transmitter now commands the motor in unstable mode. Go to step §7.2
7.2 -Test and setting the direction of rotation
Press on the UP button on the transmitter :
a- If the shaft turns in the UP direction, go to step §7.3.
b- If the motorized tube runs in the DOWN direction, reverse the rotation direction by pressing
the STOP key for at least 3 seconds. The motor will confirm the reversal of the rotation direc-
tion by running 0.5 second in both directions. Go to step §7.3.
7.3 - End limits adjustment
- The end limits of the T3.5DC EHz are adjusted
in 4 different ways depending on the following
conditions:
- Bottom slat stop or not, stiff* or flexible link between
the rolling shaft and the shutter.
A
1
B
1
1- Position the motor on the UP end limit by using the keys UP or DOWN.
2- To memorize the UP end limit position, press simultaneoulsy the keys STOP and DOWN. The motor will run automatically in the DOWN direction.
3- Press the STOP key to immobilize the motor.
4- Press 2 seconds the STOP key to validate the setting. The motor will run for half a second in one direction, then in the other direction. The operation is comple-
ted. Go to step §8.
C
1
1- Position the motor on the DOWN end limit by using the keys UP or DOWN.
2- To memorize the DOWN end limit position, press simultaneoulsy the keys STOP and UP. The motor will run automatically in the UP direction.
3- Press the STOP key to immobilize the motor.
4- Press 2 seconds the STOP key to validate the setting. The motor will run for 0.5 second in one direction, then in the other. The operation is completed. Go to
step §8.
D
1- Position the motor on the DOWN end limit by using the keys DOWN or UP.
2- To memorize the DOWN end limit position, press simultaneoulsy the keys STOP and UP. The motor will run automatically in the UP direction.
3- When the motor arrives on the UP End limit, press the key STOP.
4- If necessary adjust the position with the keys UP or DOWN.
5- To memorize the UP end limit position, press simultaneoulsy the keys STOP and DOWN. The motor will run automatically in the DOWN direction.
6- Press 2 seconds the STOP key to validate the setting. The motor will stop, and will run for 0.5 second in one direction, then in the other. The operation is com-
pleted. Go to step §8
- After these operations you can programme the transmitter used previously as the first point of control, in which case refer to chapter §8.
Conversely, to programme another transmitter as the first point of control: Press for 3 sec on the remote programming button located on the
battery pack (§5). The motor rotates briefly in one direction and then the other, then within 2 minutes perform operation 8 to confirm the
programming.
Programming the first individual control point
8
- Press the transmitter "PROG" Key for approximately one second. The motor will run for 0.5 second in one direction and
then in the other. Your transmitter is now programmed to control the motor in stable mode. All the functions
described in §11 are active.
Programming a new (individual, group or main) control point
9
9.1 - Open the memory of the motor from the control transmitter:
- Press the "PROG" key of the transmitter (or of the battery pack) for about 3 seconds. The
motor will run for 0.5 second in one direction and then in the other.
A
*V.A.R
V.A.S
Easylink
2
1- Simultaneously press the UP and DOWN keys of a Hz transmitter. The motor will run for 0.5 second in one
direction and then in the other.
2s
2- Press the "stop" key for 2 s. The motor will run for 0.5 second in one direction and then in the other. The
operation is completed. Go to step §8.
2
2
1
2
>>
>>
B
*V.A.R
V.A.S
Easylink
3
4
2s
3
4
2s
3
4
>>
OK >> 7.3
>>
>>
>>
>>
3s
C
D
5
6
2s
PROG ≤1s
3s
PROG
OK >> 7.3
3s
3 /4