Correct Electrical Installation; Safe Operation - Oase SwimSkim 50 Instrucciones De Uso

Ocultar thumbs Ver también para SwimSkim 50:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
Hazards encountered by the combination of water and electricity
 The combination of water and electricity can lead to death or severe injury from electrocution, if the unit is incorrectly
connected or misused.
 Prior to reaching into the water, always switch off the mains voltage to all units used in the water.

Correct electrical installation

 For your own safety, consult a qualified electrician if you have questions or encounter problems.
 Electrical installations in garden ponds must meet the international and national regulations valid for installers.
 Compare the electrical values of the power supply with those on the type plate on the packaging or on the unit itself.
 Only operate the unit when plugged into a correctly fitted socket.
 Please note that the power supply must be fused via a fault current protection system with a maximum reference fault
current of 30 mA.
 Only use cables that are uncoiled.
 Extension cables must be approved for outdoor use and meet DIN VDE 0620 standards.
 Route the connection cable so that damage is excluded.
 Do not carry or pull the unit by the connection cable. The power connection cable of this unit cannot be replaced. If
the cable is damaged, the entire unit has to be disposed of.
 Keep all connection points dry. Risk of electrocution.

Safe operation

 Only operate the SwimSkim CWS if no persons are in the water.
 Do not operate defective units. Never operate the unit if either the cable or the housing is defective! Pull the power
plug immediately. Repairs to the connection cable are not possible as it is cast. In the event of damage to the con-
nection cable, do not operate the SwimSkim CWS. It has to be disposed of in accordance with the regulations.
 Install the SwimSkim CWS such that any risk of injury of persons is excluded.
 Never open the housing or its attendant components, unless this is explicitly mentioned in these instructions of use.
 Only use original spare parts and accessories for the unit.
 Never use the pump for fluids other than water.
 Clean the filter basket at regular intervals.
Installation
Assesmbly of the SwimSkim CWS (Figure B, C)
1. Plug the handle (4) on the filter basket (8).
2. Fit the float switch (2):
– Start by inserting the bottom engagement hook (9) in the opening of the pump chamber provided for this purpose.
– Then press the float switch down while swinging it against the pump chamber, until the upper engagement
hook (10) audibly engages.
3. Tighten the flow-out nozzle (3) at the pump on the underside of the pump chamber.
4. Align the flow-out nozzle (3) with the flat sealing ring (14) opposite to the skimmer flap (13).
– The flow-out nozzle is correctly aligned when the arrows (11) on the underside of the unit and on the flow-out
nozzle point to one another.
Note: The blowback generated by the flow-out nozzle firmly holds the SwimSkim CWS at the securing cord or at the
securing cords (D) once fastened to the ground stakes.
5. Adjusting the flow-out nozzle (3).
– With swirl-up function: Turn the valve (12) such that the water flows out downward to swirl up the sludge from the
bottom of the pond.
– Without swirl-up function: Turn the valve (12) such that the water flows out sideways. The sludge on the bottom of
the pond is not swirled up.
6. Inserting the foam filter (7):
– If necessary, the foam filter (7) can be used to filter out fine-grain soiling (e.g. pollen).
Installing the SwimSkim CWS (Figure D)
1. Place the SwimSkim CWS into the pond.
2. Fix the SwimSkim CWS in the pond:
– Fasten at the pond edge: Fasten one securing cord each from the scope of delivery at the eyelets of two float
switches (2). Fix the securing cords at the pond edge using the ground stakes (6) such that the SwimSkim CWS
is in its desired position.
– Fasten at the bottom of the pond: Fasten one securing cord each from the scope of delivery at the two eyelets at
the unit underside (1). Fix the securing cords to the bottom of the pond, e.g. using rocks, such that the SwimSkim
CWS is in its desired position.
Note: Only put the SwimSkim CWS into use when it is firmly fixed in the pond.