Seav LRX 2281 Manual De Instrucciones página 19

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
flashing simultaneously), with the SEL key position on the flashing of PED CODE LED then
press the SET key, the PED CODE LED will simultaneously switch on permanently and
programming is completed. Repeat the procedure to restore the previous configuration.
D) INB. CMD. AP. LED (SOFT START):
The control unit is supplied by the manufacturer with the Soft Start function disabled. If
you wish to enable the function, proceed as follows: make sure that you have enabled
Extended Menu 2 (T. PAUSA LED and RIT. ANTE LED start flashing simultaneously), with
the SEL key position on the flashing of INB.CMD.AP LED then press the SET key, the
INB.CMD.AP LED will simultaneously stay on steadily and programming is completed.
Accordingly, every time the gate starts motion the control unit will control motor start-up,
increasing the power gradually from minimum to maximum in the first two seconds of
operation. Repeat the procedure to restore the previous configuration.
E) T. MOT. (Electric Lock activation CMD PED.):
The control unit is supplied by the manufacturer with the activation of the electric lock
through the disabled Pedestrian command. If you wish to enable the function, proceed as
follows: make sure that you have enabled Extended Menu 2 (T. PAUSA LED and RIT. ANTE
LED start flashing simultaneously), with the SEL key position on the flashing of T.MOT.
LED then press the SET key, the T.MOT. LED will simultaneously switch stay on steady
and programming is completed. The activation of the electric lock function through the
Pedestrian command, is used when you have, for example, a sliding gate with a door next
to the Pedestrian passage. Accordingly, the gate can be opened with the PUL commands
as well as from the Pedestrian door using the electric lock with the PED. commands.
Repeat the procedure if you wish to restore the previous configuration.
F) T. MOT. PED (PUL and PED command functions):
The control unit is factory supplied with PUL control input operation for the connection
of a cyclical primary control button (NA) and a PED input for the connection of a cyclical
Pedestrian command button (NA). If you wish to select another mode of function of the
PUL and PED inputs, proceed as follows: make sure that you have enabled Extended Menu
2 (T. PAUSA LED and RIT. ANTE LED start flashing simultaneously), by using the SEL key
select the flashing T. MOT PED. LED and press the SET button: T. MOT. PED. LED remains
steadily lit and programming is complete.
Accordingly, the PUL input makes it possible to connect a button (NA) for the Opening
phase only, and the PED input for connection to a button (NA) for the Closing phase only.
Repeat the procedure if you wish to restore the previous configuration.
EXTENDED MENU 3
The control unit is supplied by the manufacturer with the possibility of directly selecting
the main menu functions only.
To enable power programming functions for deceleration carried out by the control unit,
proceed as follows: open Extended Menu 2 (as instructed in the respective section), then
press and hold the SET key for 5 seconds, after which the T. PAUSA LED and RIT. ANTE
LED will start flashing alternately and then simultaneous, in this way there will be 30
seconds to select the desired deceleration using the SEL and SET keys, then, after a
further 30 seconds, the control unit returns to the main menu.
EXTENDED MENU 3
Level
Leds On
1
AUT / P-P
2
AUT / P-P - CODE
3
AUT / P-P – CODE – CODE PED.
4
AUT / P-P - CODE - CODE PED. - INB. CMD. AP.
5
AUT / P-P - CODE - CODE PED. – INB. CMD. AP - T. MOT.
6
AUT / P-P - CODE - CODE PED. - INB. CMD. AP - T. MOT. - T.MOT.PED.
Programming Motor Power during Deceleration
The control unit allows you to programme the motor power to which the deceleration
phase will be carried out.
It is possible to choose between 6 different levels of power in this way: every combination
of lit LEDs corresponds to a level according to the table above; in other words, starting
from the lowest LED ( LED AUT/ P-P ) and moving upwards, each LED corresponds to a
higher power level. Using the SEL key it is possible to scroll through the different power
levels; for every selected power level, the highest respective LED will flash (for example,
if level 4 is selected the AUT/ P-P, CODE and CODE PED LEDs light up steady, whereas the
INB CMD. AP LED flashes); press SET to confirm.
Level 3 is selected in the default configuration.
RESET:
To reset the default configuration of the control unit, press the SEL and SET buttons simul-
taneously; all RED signal Leds will switch on and then immediately off again.
DIAGNOSTICS:
Photocell Test: The control unit is designed for the connection of safety devices that
comply with point 5.1.1.6 of standard EN 12453. With every operation cycle, it performs a
test of the operating photocells connected. If there is no connection and/or non operation,
the control unit does not enable gate motion, and will visually report the failed test by
simultaneously flashing all of the LED signal lights flash. Once the photocells are running
correctly again, the control unit is ready for normal operation. This ensures monitoring
against failures, in compliance with EN 954-1, Category 2.
Control input test: On each low voltage control input, the control unit uses a LED signal
to make the status readily known.
Operating logic: when a LED is on it means the input is closed, when a LED is off it means
the input is open.
LED MANAGEMENT:
After 3 minutes of inactivity in the programming procedure, there is the automatic shut-
down of the Leds for energy savings. A single press of the SEL or SET key, or a movement
command will activate the LED light up according to settings programmed previously.
19
Rev. 3.0 dated 05-07-2017

Publicidad

Tabla de contenido
loading

Tabla de contenido