Part list for Jøtul F 600
Pos.
no. Description
2
Tube Frame Holder
3
Handle
4
Ash House Compl.
5
Ash Door
6
Smoke Outlet
7
Fire Grate
8
Leg
9
Decorative Cover Side
10 Door Right w/o Glass, Ver 3
11 Door Left w/o Glass, Ver 3
12 Bottom
13 Inner Bottom, Front Part
14 Inner Bottom, Rear Part
15 Rear Plate
17 Air Manifold
18 Front
19 Inner Front
20 Side Right
21 Side Left
22 Ash Lip Front
23 Top
24 Tube Holder Upper Right
25 Tube Holder Upper Left
26 Tube Holder Bottom Right
27 Tube Holder Bottom Left
28 Inspection Cover
29 Side Door
30 Burnplate Side Door
31 Burnplate Left
32 Burnplate Rear
33 Ash Lip Side
34 Air Valve
35 Baffle Plate
36 Top Cover
37 Nut Stainless
38 Screw Hexagon Stainless
39 Screw Hexagon
40 Screw Collar Hexagon
41 Screw Collar Hexagon
42 Screw Selfthread
43 Screw Collar Hexagon
44 Screw Collar Hexagon
45 Nut Hexagon
46 Screw Panh. (Front Door)
47 Washer
48 Latch Bolt Ash Door
49 Screw Allen
50 Screw Hexagon Stainless
51 Screw Collar Hexagon
52 Screw Collar Hexagon
53 Screw Collar Hexagon
54 Nut Collar Hexagon
55 Washer
56 Wooden Knob Ash Door
57 Spring for Latch Bolt
58 Hinge Pin Front/Side Door
59 Screw Syl. Head
60 Gasket (Door to Front)
61 Latch
62 Latch Bolt
63 Glass Clip
64 Ash Pan
65 Handle for Air Vent
68 Hinge Pin, Ash Door
69 Gasket (Ash Door)
70 Gasket (Glass)
71 Gasket (Top)
72 Gasket (Ash House)
73 Gasket (Left Door Middle)
74 Sleeve for Door Hinge
75 Gasket (Side Door)
76 Gasket (Smoke Outlet)
77 Tube First From Front
78 Tube Second From Front
79 Tube Third From Front
80 Tube Forth From Front
82 Bottom Heatshield
83 Heatshield Top Exit
84 Rear Heatshield
Pos.
no. Description
85 Air Restrictor
86 Insulation Blanket
87 Glass
88 Front Door Hinge
89 Gasket (Top Cover)
90 Shaft Collar Ø6 X Ø12 X 6 mm
91 Latch Bolt Side Door
92 Washer
93 Latch
94 Washer
95 Washer, Insulating
96 Wooden Knob Side Door
97 Distance Sleeve for Side Door
98 Screw Pan Head
99 Pin
100 Air Chamber Complete
101 Handle Side Door Complete
102 Adapter Outside Air
Alternate floor protection
All floor protection materials must be non-combustible ie. metal,
brick, stone, mineral fiber boards). Any combustible material may
not be used.
The easiest means of determining if a proposed alternate floor
material meets requirements listed in this manual is to follow
this procedure.
R-value = thermal resistance
k-value = thermal conductivity
C-value = thermal conductance
1. Convert the specification to R-value;
a. If R-value is given, no conversion is needed.
b. If k-value is given with a required thickness (T) in inches:
R=1/k X T.
c. If C-value is given: R=1/C.
2. Determine the R-value of the proposed alternate floor
protector.
a. Use the formula in Step 1 to convert values not expressed
as "R".
b. For multiple layers, add R-values of each layer to
determine overall R-value.
3. If the overall R-value of the system is greater than the R-value
of the specified floor protector, the alternate is acceptable.
Example:
The specified floor protector should be 3/4" thick material with a
k-factor of 0.84. The proposed alternate is 4" brick with a C-factor
of 1.25 over 1/8" mineral board with a k-factor of 0.29.
Step A. Use formula above to convert specifications
to R-value. R=1/k X T= 1/.84 X .75 = .893
Step B. Calculate R of proposed system.
4" brick of C-1.25, therefore
R brick = 1/C = 1/1.25 = 0.80.
1/8" mineral board of k = 0.29 therefore
R mineral board = 1/.29 X 0.125 = 0.431
Total R = R brick + R mineral board=
0.8 + 0.431=1.231
Step C. Compare proposed system R = 1.231 to specified R of 0.893.
Since R is greater than required, the system is acceptable.
Definitions:
Thermal conductance =
C =
Btu
=
(hr)(ft
)(F)
(m
2
Thermal conductivity =
k =
Btu
=
W
(hr)(ft
)(F)
(m
)(K)
2
2
Thermal resistance =
R =
Btu
=
(hr)(ft
)(F)
W
2
Alcove installations require noncombustible hearth materials
having a minimum insulating R-value of 0.5.
USA/cAnAdA
W
)(K)
2
=
(Btu)
(hr)(ft)(F)
(m
)(K)
=
(Btu)(inch)
2
(hr)(ft
)(F)
2
19