INSTRUCTIONS & PARTS LIST FOR SR9A-25 & SR9AY-25 SKIN CLAMP RUNNER
Read and understand "Safety Instructions For Air Tools" and these instructions before
AIR SUPPLY
The efficiency of the tool is dependent on the proper supply of clean dry air at 90 psig (6.2 bar). The use of a line filter, pressure
regulator, and lubricator will insure maximum output and life of tools. Before connecting tool, blow out the air line to remove water
and dirt which may have accumulated.
HOSE AND HOSE CONNECTIONS
Supply hose should be not less than 1/4" (6.4 mm) I.D. Extension hoses should be at least 3/8" (10 mm) I.D. Use couplings and
fittings with at least 3/8" (10mm) I.D.
LUBRICATION
Use SIOUX No. 288 air motor oil. An airline lubricator, set to deliver 2 to 4 drops per minute, is recommended. If a lubricator is
not used, add .04 oz. (1.2cc, 12 to 15 drops) of oil into the air inlet twice daily.
Lubricate the gearing every 100 hours of operation with SIOUX No. 289A grease.
GENERAL OPERATION
This tool is used to install skin clamps that temporarily hold components together. Skin clamps are often called by other names,
such as "Cleco clamps", "Kwick-Loc", "Wedgelok", and sheet metal holders. To install skin clamps, place the nose piece of the
tool over the outer body of skin clamp. Engage the tool driver on the threaded 1/4" (6.4 mm) nut of the skin clamp. Pull the trigger
and run the tool until it stalls. To remove the skin clamp, follow the above procedure, but reverse the rotation of the tool.
Motor speed may be controlled by adjusting the slotted head screw in the trigger.
The direction of spindle rotation is controlled by the reversing button. When the button is depressed, the spindle rotates
counterclockwise. Always depress the button fully to obtain full power. The reversing button can be locked in the reverse
direction by fully depressing and rotating the button clockwise.
We, Sioux Tools Inc., 250 Snap-on Drive, P.O. Box 1596, Murphy, NC, 28906, USA, declare under our sole responsibility that the products
to which this declaration relates are in conformity with the following standard or standards or other normative document or documents:
July 1, 2003
Murphy, North Carolina, USA
Date and place of issues
SERIAL "A"
operating this tool.
SOUND AND VIBRATION READINGS
*Sound Pressure
Catalog No.
dBA
SR9A-25
77.9
SR9AY-25
77.9
*per PN8NTC1
DECLARATION OF CONFORMITY
SR9A-25, SR9AY-25
EN 792 (draft), EN 292 Parts 1&2, ISO 8662, Pneurop PN8NTC1
following the provisions of
89/392/EEC as amended by 91/368/EEC & 93/44/EC Directives.
Gerald E. Seebeck
President
Sioux Tools Inc.
Name and position of issuer
*Sound Power
*Vibration
2
dBA
m/s
89.5
Less Than 2.5
89.5
Less Than 2.5
*per PN8NTC1
*per ISO 8662
1
Form ZCE639
Date 2003July25/D
Page 1 of 12
Signature of issuer